With some of the noninvasive electrophysiological measurement applications benefiting from simultaneous collection of data via both conventional disc electrodes and concentric ring electrodes, an emulation of the former by the outer ring of the latter was previously proposed and has since been used widely. Its effectiveness was validated using linear time and frequency domain signal synchrony measures (cross-correlation and coherence respectively) on both phantom model data and resting electroencephalogram from six healthy human subjects. However, application of a nonlinear signal synchrony measure (normalized mutual information) in this study resulted in mean values of less than 0.7 on both phantom model and human electroencephalogram datasets indicating that the outer ring of a tripolar concentric ring electrode may not be as suitable as an emulation of the disc electrode as previously suggested. Therefore, alternative options like the central disc or the middle ring will need to be assessed in the future work.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10980659
Primary Topic
Ocular and Laser Science Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Normalized Mutual Information in Phantom Model and Human Electroencephalogram Data for Emulation of Conventional Disc Electrode via the Outer Ring of Tripolar Concentric Ring Electrode

Oleksandr Makeyev, Yiyao Ye-Lin, Javier Garcia‐Casado, Alana Benally et al.
Ocular and Laser Science Research
article

Normalized Mutual Information in Phantom Model and Human Electroencephalogram Data for Emulation of Conventional Disc Electrode via the Outer Ring of Tripolar Concentric Ring Electrode

Oleksandr Makeyev, Yiyao Ye-Lin, Javier Garcia‐Casado, Alana Benally, Sheldon Chee, Gema Prats-Bolud
article en

Abstract

With some of the noninvasive electrophysiological measurement applications benefiting from simultaneous collection of data via both conventional disc electrodes and concentric ring electrodes, an emulation of the former by the outer ring of the latter was previously proposed and has since been used widely. Its effectiveness was validated using linear time and frequency domain signal synchrony measures (cross-correlation and coherence respectively) on both phantom model data and resting electroencephalogram from six healthy human subjects. However, application of a nonlinear signal synchrony measure (normalized mutual information) in this study resulted in mean values of less than 0.7 on both phantom model and human electroencephalogram datasets indicating that the outer ring of a tripolar concentric ring electrode may not be as suitable as an emulation of the disc electrode as previously suggested. Therefore, alternative options like the central disc or the middle ring will need to be assessed in the future work.

Diné College (US)
National Science Foundation
Openalex Percentile: Top 83%
Ocular and Laser Science Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Normalized Mutual Information in Phantom Model and Human Electroencephalogram Data for Emulation of Conventional Disc Electrode via the Outer Ring of Tripolar Concentric Ring Electrode — Oleksandr Makeyev, Yiyao Ye-Lin, et al. · (2025) | TGRS Research Map | TGRS