Automated 3D Segmentation of Glomeruli in Human Kidney Tissue Specimens Using 16.4 T MRI Without Contrast Agents

Accurate and fast assessment of glomerular number in ex vivo human kidney specimens is challenging. Glomerular number is traditionally estimated using measurements on glomerular profiles, the two-dimensional samples of glomeruli seen in histological sections. Such an approach relies on complex tissue preparation protocols, specialised equipment, and staff trained to manually count glomeruli. It is labour intensive, time-consuming, and can damage the samples studied, limiting complementary analysis with other methods. In this study, we show that glomeruli can be imaged in human nephrectomy samples at ultra-high field (16.4 T) MRI without contrast agents. A three-dimensional segmentation pipeline was developed to use high-resolution MR images (30 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mu \mathrm{m}$</tex> isotropic resolution) to accurately estimate the number of nephrons in a sample in a fully automated manner. An independent stereological method, the physical disector/fractionator combination, was used to validate the estimates of glomerular number obtained using MRI. Statistical analyses showed a good agreement between the two methods.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10980815
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Automated 3D Segmentation of Glomeruli in Human Kidney Tissue Specimens Using 16.4 T MRI Without Contrast Agents

David C. Reutens, John F. Bertram, Luise A. Cullen‐McEwen, Nyoman D. Kurniawan et al.
Advanced X-ray and CT Imaging
article

Automated 3D Segmentation of Glomeruli in Human Kidney Tissue Specimens Using 16.4 T MRI Without Contrast Agents

David C. Reutens, John F. Bertram, Luise A. Cullen‐McEwen, Nyoman D. Kurniawan, Helen Healy, Shekhar S. Chandra, Andrew J. Kassianos, A. Amar
article en

Abstract

Accurate and fast assessment of glomerular number in ex vivo human kidney specimens is challenging. Glomerular number is traditionally estimated using measurements on glomerular profiles, the two-dimensional samples of glomeruli seen in histological sections. Such an approach relies on complex tissue preparation protocols, specialised equipment, and staff trained to manually count glomeruli. It is labour intensive, time-consuming, and can damage the samples studied, limiting complementary analysis with other methods. In this study, we show that glomeruli can be imaged in human nephrectomy samples at ultra-high field (16.4 T) MRI without contrast agents. A three-dimensional segmentation pipeline was developed to use high-resolution MR images (30 <tex xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">$\mu \mathrm{m}$</tex> isotropic resolution) to accurately estimate the number of nephrons in a sample in a fully automated manner. An independent stereological method, the physical disector/fractionator combination, was used to validate the estimates of glomerular number obtained using MRI. Statistical analyses showed a good agreement between the two methods.

The University of Queensland (AU), Australian Regenerative Medicine Institute (AU), Monash University (AU)
Openalex Percentile: Top 91%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.