EPI-NAF: Enhancing Neural Attenuation Fields for Limited-Angle CT with Epipolar Consistency Conditions

Neural field methods, initially successful in the inverse rendering domain, have recently been extended to CT reconstruction, marking a paradigm shift from traditional techniques. While these approaches deliver state-of-the-art results in sparse-view CT reconstruction, they struggle in limited-angle settings, where input projections are captured over a restricted angle range. We present a novel loss term based on consistency conditions between corresponding epipolar lines in X-ray projection images, aimed at regularizing neural attenuation field optimization. By enforcing these consistency conditions, our approach, Epi-NAF, propagates supervision from input views within the limited-angle range to predicted projections over the full cone-beam CT range. This loss results in both qualitative and quantitative improvements in reconstruction compared to baseline methods.

Authors

Institutions

Publication Details

Published
2025-04-14
DOI
https://doi.org/10.1109/isbi60581.2025.10981301
Primary Topic
Medical Imaging Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EPI-NAF: Enhancing Neural Attenuation Fields for Limited-Angle CT with Epipolar Consistency Conditions

Or Litany, Tzofi Klinghoffer, Daniel Gilo
Medical Imaging Techniques and Applications
article

EPI-NAF: Enhancing Neural Attenuation Fields for Limited-Angle CT with Epipolar Consistency Conditions

Or Litany, Tzofi Klinghoffer, Daniel Gilo
article en

Abstract

Neural field methods, initially successful in the inverse rendering domain, have recently been extended to CT reconstruction, marking a paradigm shift from traditional techniques. While these approaches deliver state-of-the-art results in sparse-view CT reconstruction, they struggle in limited-angle settings, where input projections are captured over a restricted angle range. We present a novel loss term based on consistency conditions between corresponding epipolar lines in X-ray projection images, aimed at regularizing neural attenuation field optimization. By enforcing these consistency conditions, our approach, Epi-NAF, propagates supervision from input views within the limited-angle range to predicted projections over the full cone-beam CT range. This loss results in both qualitative and quantitative improvements in reconstruction compared to baseline methods.

Technion – Israel Institute of Technology (IL), Massachusetts Institute of Technology (US)
National Defense Science and Engineering Graduate
Zero hunger
Openalex Percentile: Top 85%
Medical Imaging Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.