Factors influencing spinal anesthesia-to-delivery interval in elective cesarean sections: A retrospective analysis

Previous research has shown that longer intervals from spinal anesthesia (SA) to cesarean delivery are associated with lower umbilical arterial pH levels. This study aimed to identify specific risk factors related to SA-to-delivery interval in elective cesarean sections. In this retrospective analysis, 404 singleton parturients who underwent elective cesarean sections with SA after 37 weeks of gestation were assessed. Factors influencing the SA-to-delivery interval were explored. The correlation between SA-to-delivery interval and umbilical arterial pH levels was also investigated in our cohort. Factors that significantly prolonged the SA-to-delivery interval included higher body mass index (BMI; regression coefficient [RC]: 0.206, P = .003), history of previous cesarean section (RC: 1.699, P = .012), placenta previa/low-lying placenta (RC: 6.141, P < .001), and local anesthetic administration into the epidural space following SA (RC: 3.279, P < .001). The SA-to-delivery interval was slightly yet significantly inversely correlated with umbilical arterial pH (r = -0.163, P = .001). A general linear model, adjusted for age, BMI, predominant ephedrine use, lowest systolic blood pressure between SA and delivery, diabetes mellitus, and hypertensive disorder of pregnancy have established the significant relationship between the SA-to-delivery interval and umbilical arterial pH (RC: -0.0012, P < .001). In conclusion, factors such as higher BMI, previous cesarean sections, placenta previa/low-lying placenta, and local anesthetic administration into the epidural space after SA significantly contributed to extended SA-to-delivery intervals. The SA-to-delivery interval was inversely correlated with umbilical arterial pH.

Authors

Institutions

Publication Details

Journal
Medicine
Published
2025-05-09
DOI
https://doi.org/10.1097/md.0000000000042420
Primary Topic
Cardiac, Anesthesia and Surgical Outcomes
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors influencing spinal anesthesia-to-delivery interval in elective cesarean sections: A retrospective analysis

Rikako Takahashi, Michiko Kinoshita, Yoko Sakai, Katsuya Tanaka et al.
Medicine
Cardiac, Anesthesia and Surgical Outcomes
article

Factors influencing spinal anesthesia-to-delivery interval in elective cesarean sections: A retrospective analysis

Rikako Takahashi, Michiko Kinoshita, Yoko Sakai, Katsuya Tanaka, Yoshimi Nakaji, Y Matsumoto
article en

Abstract

Previous research has shown that longer intervals from spinal anesthesia (SA) to cesarean delivery are associated with lower umbilical arterial pH levels. This study aimed to identify specific risk factors related to SA-to-delivery interval in elective cesarean sections. In this retrospective analysis, 404 singleton parturients who underwent elective cesarean sections with SA after 37 weeks of gestation were assessed. Factors influencing the SA-to-delivery interval were explored. The correlation between SA-to-delivery interval and umbilical arterial pH levels was also investigated in our cohort. Factors that significantly prolonged the SA-to-delivery interval included higher body mass index (BMI; regression coefficient [RC]: 0.206, P = .003), history of previous cesarean section (RC: 1.699, P = .012), placenta previa/low-lying placenta (RC: 6.141, P < .001), and local anesthetic administration into the epidural space following SA (RC: 3.279, P < .001). The SA-to-delivery interval was slightly yet significantly inversely correlated with umbilical arterial pH (r = -0.163, P = .001). A general linear model, adjusted for age, BMI, predominant ephedrine use, lowest systolic blood pressure between SA and delivery, diabetes mellitus, and hypertensive disorder of pregnancy have established the significant relationship between the SA-to-delivery interval and umbilical arterial pH (RC: -0.0012, P < .001). In conclusion, factors such as higher BMI, previous cesarean sections, placenta previa/low-lying placenta, and local anesthetic administration into the epidural space after SA significantly contributed to extended SA-to-delivery intervals. The SA-to-delivery interval was inversely correlated with umbilical arterial pH.

MedicineVol. 104(19)
Tokushima University Hospital (JP)
Good health and well-being
Openalex Percentile: Top 82%
Cardiac, Anesthesia and Surgical Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.