Post-Treatment of Microbrewery Effluent Through Coagulation and Rapid Filtration

This study evaluated the efficiency of double and triple filtration technology associated with coagulation as a post-treatment of microbrewery effluent from an anaerobic decant-digester (ADD). The coagulants used were ferric chloride (FeCl₃), polyaluminum chloride (PAC), and a tannin-based natural coagulant (TAN). The filtration rate used was 120 m³/m²/day. The efficiency of the system was evaluated through physicochemical parameters. The post-treatment, which combined coagulation and triple filtration, achieved removals of 98% for apparent color, 64% for Chemical Oxygen Demand (COD), 59% for Biochemical Oxygen Demand (BOD), 100% for Phenols, 99% for Total Phosphorus (TP), 77% for Total Kjeldahl Nitrogen (TKN), 96% for Total Suspended Solids (TSS) and 99% for Turbidity, with results varying according to the coagulant used. Results indicated that PAC was the most efficient coagulant at lower concentrations, followed by TAN and FeCl₃. The post-treatment system proved to be highly effective in contaminant removal, offering a promising solution for the treatment of microbrewery effluents.

Authors

Institutions

Publication Details

Journal
Orbital - The Electronic Journal of Chemistry
Published
2025-05-02
DOI
https://doi.org/10.17807/orbital.v17i1.22274
Primary Topic
Wastewater Treatment and Reuse
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Post-Treatment of Microbrewery Effluent Through Coagulation and Rapid Filtration

Sandro Xavier de Campos, Amanda Vedam Pupin, Cleber Pinto da Silva
Orbital - The Electronic Journal of Chemistry
Wastewater Treatment and Reuse
article

Post-Treatment of Microbrewery Effluent Through Coagulation and Rapid Filtration

Sandro Xavier de Campos, Amanda Vedam Pupin, Cleber Pinto da Silva
article en

Abstract

This study evaluated the efficiency of double and triple filtration technology associated with coagulation as a post-treatment of microbrewery effluent from an anaerobic decant-digester (ADD). The coagulants used were ferric chloride (FeCl₃), polyaluminum chloride (PAC), and a tannin-based natural coagulant (TAN). The filtration rate used was 120 m³/m²/day. The efficiency of the system was evaluated through physicochemical parameters. The post-treatment, which combined coagulation and triple filtration, achieved removals of 98% for apparent color, 64% for Chemical Oxygen Demand (COD), 59% for Biochemical Oxygen Demand (BOD), 100% for Phenols, 99% for Total Phosphorus (TP), 77% for Total Kjeldahl Nitrogen (TKN), 96% for Total Suspended Solids (TSS) and 99% for Turbidity, with results varying according to the coagulant used. Results indicated that PAC was the most efficient coagulant at lower concentrations, followed by TAN and FeCl₃. The post-treatment system proved to be highly effective in contaminant removal, offering a promising solution for the treatment of microbrewery effluents.

Orbital - The Electronic Journal of Chemistry
Universidade Estadual de Ponta Grossa (BR)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior
Openalex Percentile: Top 88%
Wastewater Treatment and Reuse
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Post-Treatment of Microbrewery Effluent Through Coagulation and Rapid Filtration — Sandro Xavier de Campos, Amanda Vedam Pupin, et al. · Orbital - The Electronic Journal of Chemistry (2025) | TGRS Research Map | TGRS