Endovascular Retrieval of Disconnected Tip From an Iliac Branch Device Stent Graft: A Case Report

Endovascular repair of aneurysmal pathology in the aorto-iliac district presents one of the significant challenges in contemporary vascular surgery. Advances in techniques, materials, and devices have enhanced the ability of vascular surgeons in endovascular procedures, leading to the management of increasingly complex cases, with applications sometimes extending beyond the Instructions for Use (IFUs) of specific devices. In our case report, we describe the successful endovascular retrieval of a disconnected tip from an iliac branch device (IBD), preventing conversion to open surgery in a 73-year-old patient with a complex aortoiliac aneurysm. The case highlights the importance of exercising caution when treating patients with complex anatomy not in conformance with a device's IFU, even in high-volume centers with extensive endovascular expertise.

Authors

Institutions

Publication Details

Journal
Annali Italiani di Chirurgia
Published
2025-05-10
DOI
https://doi.org/10.62713/aic.3784
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Endovascular Retrieval of Disconnected Tip From an Iliac Branch Device Stent Graft: A Case Report

Davide Turchino, Umberto Marcello Bracale, Antonia Rinaldi, Luca del Guercio et al.
Annali Italiani di Chirurgia
Aortic aneurysm repair treatments
article

Endovascular Retrieval of Disconnected Tip From an Iliac Branch Device Stent Graft: A Case Report

Davide Turchino, Umberto Marcello Bracale, Antonia Rinaldi, Luca del Guercio, Ilaria Calicchio, Nicola Cantile, Michele Vollono
article en

Abstract

Endovascular repair of aneurysmal pathology in the aorto-iliac district presents one of the significant challenges in contemporary vascular surgery. Advances in techniques, materials, and devices have enhanced the ability of vascular surgeons in endovascular procedures, leading to the management of increasingly complex cases, with applications sometimes extending beyond the Instructions for Use (IFUs) of specific devices. In our case report, we describe the successful endovascular retrieval of a disconnected tip from an iliac branch device (IBD), preventing conversion to open surgery in a 73-year-old patient with a complex aortoiliac aneurysm. The case highlights the importance of exercising caution when treating patients with complex anatomy not in conformance with a device's IFU, even in high-volume centers with extensive endovascular expertise.

Annali Italiani di ChirurgiaVol. 96(5)
Federico II University Hospital (IT)
Good health and well-being
Openalex Percentile: Top 84%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.