Evaluation of Settlement and Bearing Capacity of Three Selected Buildings in Ibeju Lekki, Lagos

This study assessed the geotechnical properties of soils at three locations with distressed buildings in Ibeju-Lekki, Lagos State, Nigeria. The aim was to identify possible geotechnical causes of structural impairments and ongoing deterioration, which led to occupant evacuation. Three buildings, labelled A, B, and C, were analyzed. Disturbed soil samples were collected from fourcorners at foundation depths to evaluate soil properties and their potential effects on structural performance. Index properties, including grain size distribution, moisture content, and specific gravity, were determined for soil classification. A triaxial test was conducted to determine cohesion and internal friction angles, while Terzaghi’s equations were used to estimate bearing capacities.Consolidation tests were performed to compute both immediate and final settlements, providing insights into soil behavior under load. Results showed moisture content ranging from 2.02% to 16.04%, with the lowest in sample C4 (2.02%) and the highest in B4 (16.04%). Specific gravity values ranged between 2.55 and 2.65. Soil classifications were A3 (AASHTO) and SP (USCS),indicating poorly graded sands. Mean bearing capacities for buildings A, B, and C were 102.05 kN/m², 90.54 kN/m², and 96.25 kN/m², with standard deviations of 41.35 kN/m², 26.65 kN/m², and 48.39 kN/m², respectively. Final settlements averaged 0.3 cm, 0.24 cm, and 0.34 cm, with standard deviations of 0.09 cm, 0.06 cm, and 0.2 cm. Building C exhibited higher variability insettlement and bearing capacity, suggesting greater susceptibility to further structural distress. A correlation of -0.43 between bearing capacity and settlement confirmed that lower capacities correspond to increased settlements. The study emphasizes the importance of proper soil investigations and strict adherence to geotechnical recommendations during construction to prevent failures.

Authors

Institutions

Publication Details

Journal
Uniosun Journal of Engineering and Environmental Sciences
Published
2025-05-10
DOI
https://doi.org/10.36108/ujees/5202.70.0190
Primary Topic
Construction Engineering and Safety
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of Settlement and Bearing Capacity of Three Selected Buildings in Ibeju Lekki, Lagos

A. A. Bello, R. O. Yusuff
Uniosun Journal of Engineering and Environmental Sciences
Construction Engineering and Safety
article

Evaluation of Settlement and Bearing Capacity of Three Selected Buildings in Ibeju Lekki, Lagos

A. A. Bello, R. O. Yusuff
article en

Abstract

This study assessed the geotechnical properties of soils at three locations with distressed buildings in Ibeju-Lekki, Lagos State, Nigeria. The aim was to identify possible geotechnical causes of structural impairments and ongoing deterioration, which led to occupant evacuation. Three buildings, labelled A, B, and C, were analyzed. Disturbed soil samples were collected from fourcorners at foundation depths to evaluate soil properties and their potential effects on structural performance. Index properties, including grain size distribution, moisture content, and specific gravity, were determined for soil classification. A triaxial test was conducted to determine cohesion and internal friction angles, while Terzaghi’s equations were used to estimate bearing capacities.Consolidation tests were performed to compute both immediate and final settlements, providing insights into soil behavior under load. Results showed moisture content ranging from 2.02% to 16.04%, with the lowest in sample C4 (2.02%) and the highest in B4 (16.04%). Specific gravity values ranged between 2.55 and 2.65. Soil classifications were A3 (AASHTO) and SP (USCS),indicating poorly graded sands. Mean bearing capacities for buildings A, B, and C were 102.05 kN/m², 90.54 kN/m², and 96.25 kN/m², with standard deviations of 41.35 kN/m², 26.65 kN/m², and 48.39 kN/m², respectively. Final settlements averaged 0.3 cm, 0.24 cm, and 0.34 cm, with standard deviations of 0.09 cm, 0.06 cm, and 0.2 cm. Building C exhibited higher variability insettlement and bearing capacity, suggesting greater susceptibility to further structural distress. A correlation of -0.43 between bearing capacity and settlement confirmed that lower capacities correspond to increased settlements. The study emphasizes the importance of proper soil investigations and strict adherence to geotechnical recommendations during construction to prevent failures.

Uniosun Journal of Engineering and Environmental SciencesVol. 7(1)
Osun State University (NG)
Openalex Percentile: Top 90%
Construction Engineering and Safety
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaluation of Settlement and Bearing Capacity of Three Selected Buildings in Ibeju Lekki, Lagos — A. A. Bello, R. O. Yusuff · Uniosun Journal of Engineering and Environmental Sciences (2025) | TGRS Research Map | TGRS