Permanent Epicardial Pacemaker Therapy in Paediatrics' Population in a Single Centre in Pakistan

Background: Permanent cardiac pacing is uncommon in children, and when performed, it is typically achieved through epicardial pacing. We analysed our clinical group's experience with epicardial pacemaker implantation.Objective: To assess our experience with epicardial pacemakers and to identify potential factors that could predict early and late lead-related complications.Materials and Methods: This study included 34 patients under the age of 12 who underwent implantation of an epicardial pacemaker between 2018 and 2020. A retrospective review of their medical records was conducted. The study was approved by the ethics committee of the institution. A thorough review of the cardiac surgical and pacemaker databases identified all the paediatric patients who underwent permanent epicardial pacemakers implantation at a tertiary care hospital of Peshawar. Adult patients with an age of were omitted to focus on paediatric cohort. Medical records were retrospectively studied.Results: For each patient, the average age across all PPM implantations, including any repeat procedures, was 7.2 ± 2.6 years. The average weight at the time of lead implantation was 24.8±4.0kg. The majority of patients who underwent pacemaker implantation or lead replacement surgery were discharged from the hospital within a week of the procedure. Of all the patients, 36.8% required a pacemaker due to post-op atrioventricular block, 28% had sinus node dysfunction, 20% had congenital complete heart block, and approximately 15.2% of the patients required a pacemaker for other reasons, including bradycardia caused by antiarrhythmic medication.Conclusion: The leads exhibited commendable longevity, enduring without significant variations based on their type. Lead and generator lifespan were unaffected by lead type, pacing mode, or patient age.Keywords: Epicardial pacemaker, Generator longevity, Lead longevity, Paediatric epicardial pacing, Single ventricle pacing.

Authors

Institutions

Publication Details

Journal
Journal of Saidu Medical College Swat
Published
2025-05-10
DOI
https://doi.org/10.52206/jsmc.2025.15.2.1130
Primary Topic
Coronary Artery Anomalies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Permanent Epicardial Pacemaker Therapy in Paediatrics' Population in a Single Centre in Pakistan

Faiza Gohar, Wasim Ahmad, Omar Saleem, A.K.M. Tarikuz Zaman et al.
Journal of Saidu Medical College Swat
Coronary Artery Anomalies
article

Permanent Epicardial Pacemaker Therapy in Paediatrics' Population in a Single Centre in Pakistan

Faiza Gohar, Wasim Ahmad, Omar Saleem, A.K.M. Tarikuz Zaman, Hadiqa Khushnood Qazi, Rimsha Shais, BENSELAMA Naila Fatima Zohra
article en

Abstract

Background: Permanent cardiac pacing is uncommon in children, and when performed, it is typically achieved through epicardial pacing. We analysed our clinical group's experience with epicardial pacemaker implantation.Objective: To assess our experience with epicardial pacemakers and to identify potential factors that could predict early and late lead-related complications.Materials and Methods: This study included 34 patients under the age of 12 who underwent implantation of an epicardial pacemaker between 2018 and 2020. A retrospective review of their medical records was conducted. The study was approved by the ethics committee of the institution. A thorough review of the cardiac surgical and pacemaker databases identified all the paediatric patients who underwent permanent epicardial pacemakers implantation at a tertiary care hospital of Peshawar. Adult patients with an age of were omitted to focus on paediatric cohort. Medical records were retrospectively studied.Results: For each patient, the average age across all PPM implantations, including any repeat procedures, was 7.2 ± 2.6 years. The average weight at the time of lead implantation was 24.8±4.0kg. The majority of patients who underwent pacemaker implantation or lead replacement surgery were discharged from the hospital within a week of the procedure. Of all the patients, 36.8% required a pacemaker due to post-op atrioventricular block, 28% had sinus node dysfunction, 20% had congenital complete heart block, and approximately 15.2% of the patients required a pacemaker for other reasons, including bradycardia caused by antiarrhythmic medication.Conclusion: The leads exhibited commendable longevity, enduring without significant variations based on their type. Lead and generator lifespan were unaffected by lead type, pacing mode, or patient age.Keywords: Epicardial pacemaker, Generator longevity, Lead longevity, Paediatric epicardial pacing, Single ventricle pacing.

Journal of Saidu Medical College SwatVol. 15(2)
The University of Agriculture, Peshawar (PK), Khyber Teaching Hospital (PK), Institute of Management Sciences Peshawar (PK), Shaukat Khanum Memorial Cancer Hospital and Research Center (PK)
Openalex Percentile: Top 85%
Coronary Artery Anomalies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.