The <scp>3D</scp> ‐Robotic Exoscope Compared With the Microscope in Cochlear Implant and Translabyrinthine Surgery

ABSTRACT Objectives The three‐dimensional (3D) exoscope is an innovative viewing platform in microsurgery with the potential of offering improved ergonomics and surgical performance. This study systematically evaluated the ergonomic characteristics, visualization, and subjective performance of an exoscope system compared to the microscope in cochlear implantation (CI) and translabyrinthine resection of vestibular schwannomas (VS). Methods This prospective qualitative study was performed at a tertiary referral center. Ergonomics were evaluated subjectively with questionnaires in addition to the Rapid Upper Limb Assessment Tool (RULA), which was used as a quantitative measure of ergonomic risk. Performance and visualization parameters were assessed at specific surgical milestones in comparing the exoscope to the microscope. Results Ergonomically, exoscopic surgery led to less straining in both subjective ( p &lt; 0.001) and objective ( p &lt; 0.001) measures. Visualization in terms of expansiveness, visual clarity, and depth was superior at each surgical milestone in VS (exoscope n = 7; microscope n = 5) and most of the CI milestones (exoscope n = 24; microscope n = 22). CI surgeries were completed faster with the exoscope ( p = 0.007). Conclusion The 3D‐exoscope afforded clear ergonomic advantages as compared with the microscope in so far as to reduce strains and potentially long‐term risks to surgeons. Additional advantages over the traditional surgical microscope included improvement in the field of view and visual clarity, with no effect on time to completion. Further advancements in exoscope technology will ease the adaptation of this innovative device in cochlear implant and translabyrinthe surgeries. Level of Evidence 3.

Authors

Institutions

Publication Details

Journal
The Laryngoscope
Published
2025-05-10
DOI
https://doi.org/10.1002/lary.32104
Citations
3
Primary Topic
Surgical Simulation and Training
Type
article
Field-Weighted Citation Impact
6.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The 3D ‐Robotic Exoscope Compared With the Microscope in Cochlear Implant and Translabyrinthine Surgery

Omer J. Ungar, Joseph M. Chen, Farhad Pirouzmand, Vincent Lin et al.
3 citations
The Laryngoscope
Surgical Simulation and Training
6.02
article

The 3D ‐Robotic Exoscope Compared With the Microscope in Cochlear Implant and Translabyrinthine Surgery

Omer J. Ungar, Joseph M. Chen, Farhad Pirouzmand, Vincent Lin, Trung Le, Jennifer L. Spiegel, Münir Demir Bajin, Nicole Crimi
article en
3 citations

Abstract

ABSTRACT Objectives The three‐dimensional (3D) exoscope is an innovative viewing platform in microsurgery with the potential of offering improved ergonomics and surgical performance. This study systematically evaluated the ergonomic characteristics, visualization, and subjective performance of an exoscope system compared to the microscope in cochlear implantation (CI) and translabyrinthine resection of vestibular schwannomas (VS). Methods This prospective qualitative study was performed at a tertiary referral center. Ergonomics were evaluated subjectively with questionnaires in addition to the Rapid Upper Limb Assessment Tool (RULA), which was used as a quantitative measure of ergonomic risk. Performance and visualization parameters were assessed at specific surgical milestones in comparing the exoscope to the microscope. Results Ergonomically, exoscopic surgery led to less straining in both subjective ( p &lt; 0.001) and objective ( p &lt; 0.001) measures. Visualization in terms of expansiveness, visual clarity, and depth was superior at each surgical milestone in VS (exoscope n = 7; microscope n = 5) and most of the CI milestones (exoscope n = 24; microscope n = 22). CI surgeries were completed faster with the exoscope ( p = 0.007). Conclusion The 3D‐exoscope afforded clear ergonomic advantages as compared with the microscope in so far as to reduce strains and potentially long‐term risks to surgeons. Additional advantages over the traditional surgical microscope included improvement in the field of view and visual clarity, with no effect on time to completion. Further advancements in exoscope technology will ease the adaptation of this innovative device in cochlear implant and translabyrinthe surgeries. Level of Evidence 3.

The LaryngoscopeVol. 135(7)
Sunnybrook Health Science Centre (CA), University of Toronto (CA), London Health Sciences Centre (CA), Health Sciences Centre (CA), Ludwig-Maximilians-Universität München (DE)
Openalex Percentile: Top 4%
Surgical Simulation and Training
6.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.