Investigations on Passive Solar Liquid Desiccant Regenerator under Indoor Simulated Conditions

Demand for air conditioning is rising exponentially due to improving economic conditions of large population of the world, growth of built-up space, changing lifestyles of people and higher comfort expectations. Most of the air conditioning systems use vapor compression refrigeration technology which needs electrical power to run. This has resulted in issues like higher peak demands for electrical power and higher direct and indirect emissions of greenhouse gases as well as other pollutants. The above issues can be alleviated by developing thermally activated air conditioning technologies, which use heat as the main energy source. Out of various thermally activated air conditioning technologies, liquid desiccant-based air conditioning (LDAC) systems are very attractive due to their adaptability for solar thermal energy. In LDAC systems the dehumidifier provides cooling using concentrated LD solution. This solution gets diluted there by absorbing moisture. The regenerator of LDAC systems utilizes thermal energy to remove water from the dilute LD solution to concentrate it and thus complete the cycle. The performance of the solar regenerators may be evaluated in terms of regeneration rate (moisture removal rate in ml/m2·h) and regeneration efficiency (useful heat/ solar energy input, unitless). Weather parameters like solar insolation, wind velocity, ambient temperature and system parameter like concentration affect the performance of the regenerator. The regenerator used in the current study is ‘passive solar’, meaning that no fan or pump is used in the device and solar thermal energy is the source of energy. Regression analysis of full factorial study was done using MinitabTM software to understand the effect of various parameters on performance of the passive solar regenerator. It is observed that as independent parameters, solar insolation, ambient temperature and concentration of LD have significant effect on the performance of the solar passive regenerator. The pareto chart shows that solar insolation has the most prominent effect on performance followed by the concentration of LD. Solar insolation has a positive effect on performance while higher concentration affects the performance negatively. The interaction plot for regeneration rate shows that solar insolation, when paired with other parameters, also has a considerable effect on the performance. The two-way interaction of wind velocity and concentration also has significant effect on the performance. Using ANOVATM, it was seen that the full factorial experiment design is linear. The insights developed in current work would help decide viability of using the passive solar regenerator at a given location and deciding the concentration range to be used in LDAC systems.

Authors

Institutions

Publication Details

Journal
CONECT International Scientific Conference of Environmental and Climate Technologies
Published
2025-05-09
DOI
https://doi.org/10.7250/conect.2025.055
Primary Topic
Solar-Powered Water Purification Methods
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigations on Passive Solar Liquid Desiccant Regenerator under Indoor Simulated Conditions

Jignasu P. Mehta, S. Indira Gandhi, Jaydeep M. Bhatt
CONECT International Scientific Conference of Environmental and Climate Technologies
Solar-Powered Water Purification Methods
article

Investigations on Passive Solar Liquid Desiccant Regenerator under Indoor Simulated Conditions

Jignasu P. Mehta, S. Indira Gandhi, Jaydeep M. Bhatt
article en

Abstract

Demand for air conditioning is rising exponentially due to improving economic conditions of large population of the world, growth of built-up space, changing lifestyles of people and higher comfort expectations. Most of the air conditioning systems use vapor compression refrigeration technology which needs electrical power to run. This has resulted in issues like higher peak demands for electrical power and higher direct and indirect emissions of greenhouse gases as well as other pollutants. The above issues can be alleviated by developing thermally activated air conditioning technologies, which use heat as the main energy source. Out of various thermally activated air conditioning technologies, liquid desiccant-based air conditioning (LDAC) systems are very attractive due to their adaptability for solar thermal energy. In LDAC systems the dehumidifier provides cooling using concentrated LD solution. This solution gets diluted there by absorbing moisture. The regenerator of LDAC systems utilizes thermal energy to remove water from the dilute LD solution to concentrate it and thus complete the cycle. The performance of the solar regenerators may be evaluated in terms of regeneration rate (moisture removal rate in ml/m2·h) and regeneration efficiency (useful heat/ solar energy input, unitless). Weather parameters like solar insolation, wind velocity, ambient temperature and system parameter like concentration affect the performance of the regenerator. The regenerator used in the current study is ‘passive solar’, meaning that no fan or pump is used in the device and solar thermal energy is the source of energy. Regression analysis of full factorial study was done using MinitabTM software to understand the effect of various parameters on performance of the passive solar regenerator. It is observed that as independent parameters, solar insolation, ambient temperature and concentration of LD have significant effect on the performance of the solar passive regenerator. The pareto chart shows that solar insolation has the most prominent effect on performance followed by the concentration of LD. Solar insolation has a positive effect on performance while higher concentration affects the performance negatively. The interaction plot for regeneration rate shows that solar insolation, when paired with other parameters, also has a considerable effect on the performance. The two-way interaction of wind velocity and concentration also has significant effect on the performance. Using ANOVATM, it was seen that the full factorial experiment design is linear. The insights developed in current work would help decide viability of using the passive solar regenerator at a given location and deciding the concentration range to be used in LDAC systems.

CONECT International Scientific Conference of Environmental and Climate Technologies
Junagadh Agricultural University (IN), Maharaja Sayajirao University of Baroda (IN), Government of Andhra Pradesh (IN), Government of Gujarat (IN)
Openalex Percentile: Top 94%
Solar-Powered Water Purification Methods
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.