Transient stability improvement of a DFIG-based network-connected wind power plant by control of the flux neutralization current during the voltage drop

In order to protect a doubly fed induction generator (DFIG) against voltage drops, it is essential to maintain its transient stability. The passive "crowbar and dc-chopper" technique has been employed to protect DFIGs. However, it may not be sufficient for some of the transient profiles. For this reason, the Low Voltage Ride Through (LVRT) has been employed by implementing Control of Flux Neutralization Current (CFNC) for transient response assessment. Moreover, the induced electromotive forces (IEFs) in both circuits (stator and rotor) were modeled on the DFIG, and the comparative performance of the DFIG models with and without CFNC was examined. The system behavior was examined for symmetrical three-phase faults, considering the cases with and without the stator/rotor coupling dynamics. This study uses numerical modeling and time-domain simulations with MATLAB/Simulink to analyze the transient behavior of the DFIG system under fault conditions. No experimental tests have been carried out, and future work will aim at a real-time implementation to assess practical feasibility. DFIG quantities were analyzed and compared, including 0.69 kV output voltage, mechanical speed response, electromagnetic torque variations, rotor and stator direct quadrature (d-q) axis currents, 22 kV bus terminal voltage, and, a DC-Link voltage. The results reveal that CFNC reduces the duration of oscillations by more than 50%, stabilizing currents in 1.18 s instead of 3.5 s and the DC-Link voltage in 1.1 s instead of 3.5 s, significantly improving LVRT capability and transient stability.

Authors

Institutions

Publication Details

Journal
Scientific African
Published
2025-05-10
DOI
https://doi.org/10.1016/j.sciaf.2025.e02745
Primary Topic
Wind Turbine Control Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient stability improvement of a DFIG-based network-connected wind power plant by control of the flux neutralization current during the voltage drop

Hamid Chojaa, Almoataz Y. Abdelaziz, Abdelilah Hilali, Mishari Metab Almalki et al.
1 links
Scientific African
Wind Turbine Control Systems
article

Transient stability improvement of a DFIG-based network-connected wind power plant by control of the flux neutralization current during the voltage drop

Hamid Chojaa, Almoataz Y. Abdelaziz, Abdelilah Hilali, Mishari Metab Almalki, Said Mahfoud, Azeddine Loulijat, Mahmoud A. Mossa, Mohamed Makhad
article en

Abstract

In order to protect a doubly fed induction generator (DFIG) against voltage drops, it is essential to maintain its transient stability. The passive "crowbar and dc-chopper" technique has been employed to protect DFIGs. However, it may not be sufficient for some of the transient profiles. For this reason, the Low Voltage Ride Through (LVRT) has been employed by implementing Control of Flux Neutralization Current (CFNC) for transient response assessment. Moreover, the induced electromotive forces (IEFs) in both circuits (stator and rotor) were modeled on the DFIG, and the comparative performance of the DFIG models with and without CFNC was examined. The system behavior was examined for symmetrical three-phase faults, considering the cases with and without the stator/rotor coupling dynamics. This study uses numerical modeling and time-domain simulations with MATLAB/Simulink to analyze the transient behavior of the DFIG system under fault conditions. No experimental tests have been carried out, and future work will aim at a real-time implementation to assess practical feasibility. DFIG quantities were analyzed and compared, including 0.69 kV output voltage, mechanical speed response, electromagnetic torque variations, rotor and stator direct quadrature (d-q) axis currents, 22 kV bus terminal voltage, and, a DC-Link voltage. The results reveal that CFNC reduces the duration of oscillations by more than 50%, stabilizing currents in 1.18 s instead of 3.5 s and the DC-Link voltage in 1.1 s instead of 3.5 s, significantly improving LVRT capability and transient stability.

Scientific AfricanVol. 28
Mohammed V University (MA), Future University in Egypt (EG), Université Sultan Moulay Slimane (MA), Université Hassan 1er (MA), Université Moulay Ismail de Meknes (MA), Al Baha University (SA), Sidi Mohamed Ben Abdellah University (MA), Minia University (EG)
Affordable and clean energy
Openalex Percentile: Top 92%
Wind Turbine Control Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.