Noninvasive blood pressure monitoring by PPG based on neural networks

In this study, a hybrid neural network multi-input multi-output blood pressure prediction model based on self-attention mechanism autoencoder (CAE-SA-MIMO-CNN) is expected to output two different predictive values (systolic and diastolic blood pressure) using PPG signal waves. photoplethysmography (PPG) was used for continuous non-invasive blood pressure monitoring. In this study, a CAE-SA-MIMO-CNN hybrid neural network model was constructed. PPG signals from the medical information set of our university, physiological data of the tester and discrete blood pressure values were used to simultaneously record signal data. PPG signal waves were preprocessed and input into the model to process signal data and static features. The final output is two different predicted values (systolic and diastolic blood pressure).When CAE-SA-MIMO-CNN neural network with window length 700 was used, the error between the predicted blood pressure value and the actual blood pressure value was the smallest, and the confidence of the homologous T test was above 95%, and the average blood pressure error was 4.76 mmHg and 9.065 mmHg, respectively. The predicted blood pressure value and the actual blood pressure value had good consistency and correlation. According to the standards of the Association for the Advancement of Medical Instrumentation (AAMI).

Authors

Institutions

Publication Details

Published
2025-01-10
DOI
https://doi.org/10.1145/3724979.3725007
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noninvasive blood pressure monitoring by PPG based on neural networks

Meihua Song, Yining Lin, Xudong Liu, Lei He
1 citations
Non-Invasive Vital Sign Monitoring
0.67
article

Noninvasive blood pressure monitoring by PPG based on neural networks

Meihua Song, Yining Lin, Xudong Liu, Lei He
article en
1 citations

Abstract

In this study, a hybrid neural network multi-input multi-output blood pressure prediction model based on self-attention mechanism autoencoder (CAE-SA-MIMO-CNN) is expected to output two different predictive values (systolic and diastolic blood pressure) using PPG signal waves. photoplethysmography (PPG) was used for continuous non-invasive blood pressure monitoring. In this study, a CAE-SA-MIMO-CNN hybrid neural network model was constructed. PPG signals from the medical information set of our university, physiological data of the tester and discrete blood pressure values were used to simultaneously record signal data. PPG signal waves were preprocessed and input into the model to process signal data and static features. The final output is two different predicted values (systolic and diastolic blood pressure).When CAE-SA-MIMO-CNN neural network with window length 700 was used, the error between the predicted blood pressure value and the actual blood pressure value was the smallest, and the confidence of the homologous T test was above 95%, and the average blood pressure error was 4.76 mmHg and 9.065 mmHg, respectively. The predicted blood pressure value and the actual blood pressure value had good consistency and correlation. According to the standards of the Association for the Advancement of Medical Instrumentation (AAMI).

Anhui Xinhua University (CN), Guangzhou Xinhua University
Openalex Percentile: Top 32%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.