Using Electroosmotic Pumps to Control the Flow Velocity in Cotton Thread‐Based µTADs
Flow velocity control is of great interest for passive microfluidic devices that are used in point-of-care diagnostics. Various methods have been developed for the flow velocity control of microfluidic paper-based analytical devices (µPADs), whereas fewer attempts have been made for microfluidic thread-based analytical devices (µTADs). In this research, we attempt to control the flow velocity in cotton thread-based µTADs with electroosmotic pumping. Utilizing electroosmotic pumps, the flow velocity in the cotton thread-based µTADs can be decreased or increased by 13% and 106%, respectively. Moreover, the dynamic control of the flow velocity in the cotton thread-based µTADs is achieved by adjusting the real-time magnitude and direction of the voltage. Furthermore, we demonstrate that electroosmotic pumps can be used to overcome the hydrophobic valves in the cotton thread-based µTADs. We show that the delivery sequence of different liquid samples for a three-branch µTAD can be controlled. Finally, we show the potential application in lithium detection with a colorimetric assay. This method for flow velocity control shows promise for customizing the flow velocity and reaction time of cotton thread-based µTADs, and this method can potentially increase the sensitivity of detection.
Authors
- Qinghao He (ORCID: https://orcid.org/0000-0002-7532-3715)
- Zitong Ye
- Zejingqiu Chen
- Lok Ting Chu (ORCID: https://orcid.org/0000-0002-6791-7468)
- Xinyi Chen (ORCID: https://orcid.org/0000-0002-6990-5233)
- Zitao Feng (ORCID: https://orcid.org/0000-0002-8618-0852)
- Weijin Guo (ORCID: https://orcid.org/0000-0003-2444-6771)
- Xionghui Li (ORCID: https://orcid.org/0009-0007-3737-5411)
- Yeqian Liu
- Jie Zhou (ORCID: https://orcid.org/0000-0001-5730-4521)
- Xingwei Zhang (ORCID: https://orcid.org/0000-0001-9513-9299)
- Huilin Chen (ORCID: https://orcid.org/0000-0003-3082-5997)
- Muyang Zhang (ORCID: https://orcid.org/0000-0001-6286-0434)
- Ziwei Huang (ORCID: https://orcid.org/0000-0003-2070-8981)
- Huiru Zhang (ORCID: https://orcid.org/0000-0002-9030-1514)
- Xuanying Liang
- Haonan Li (ORCID: https://orcid.org/0009-0004-1982-8710)
Institutions
- Guangdong Medical College (CN)
- Shantou University (CN)
Publication Details
- Journal
- Electrophoresis
- Published
- 2025-05-10
- DOI
- https://doi.org/10.1002/elps.8153
- Primary Topic
- Biosensors and Analytical Detection
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- Shantou University
- National Natural Science Foundation of China
- Department of Education of Guangdong Province
- Basic and Applied Basic Research Foundation of Guangdong Province