Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building-A Review

This study investigates the influence of miss-tuning in multiple tuned liquid sloshing dampers (MTLSDs) on the wind-induced response of a 76-story benchmark tall building.The sloshing behaviour of the liquid within the dampers is modelled using shallow water wave theory, and the governing equations of motion for the combined structure-damper system are expressed in a state-space framework for numerical analysis.Comparative outcomes between the uncontrolled structure and the structure that is installed with MTLSDs reveal a very significant reduction in structural responses due to the incorporation of the dampers.Though the traditional tuned liquid sloshing dampers (TLSDs) are marginally more efficient at optimal tuning conditions, MTLSDs show higher performance at miss-tuning conditions.They efficiently keep the structural response within acceptable levels as specified by motion perception criteria and provide greater control over upper mode responses than TLSDs, deciding their strength under practical conditions.

Publication Details

Journal
IARJSET
Published
2025-05-10
DOI
https://doi.org/10.17148/iarjset.2025.125175
Primary Topic
Vibration Control and Rheological Fluids
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building-A Review

IARJSET
Vibration Control and Rheological Fluids
article

Multiple tuned liquid sloshing dampers for across-wind response control of benchmark tall building-A Review

article en

Abstract

This study investigates the influence of miss-tuning in multiple tuned liquid sloshing dampers (MTLSDs) on the wind-induced response of a 76-story benchmark tall building.The sloshing behaviour of the liquid within the dampers is modelled using shallow water wave theory, and the governing equations of motion for the combined structure-damper system are expressed in a state-space framework for numerical analysis.Comparative outcomes between the uncontrolled structure and the structure that is installed with MTLSDs reveal a very significant reduction in structural responses due to the incorporation of the dampers.Though the traditional tuned liquid sloshing dampers (TLSDs) are marginally more efficient at optimal tuning conditions, MTLSDs show higher performance at miss-tuning conditions.They efficiently keep the structural response within acceptable levels as specified by motion perception criteria and provide greater control over upper mode responses than TLSDs, deciding their strength under practical conditions.

IARJSETVol. 12(5)
Affordable and clean energy
Openalex Percentile: Top 90%
Vibration Control and Rheological Fluids
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.