Overheating Risk Assessment in Passive Energy Innovations in Spain

The regulations of the European Union (EU) demand the improvement of the energy efficiency of buildings. Following this, thermal insulation-based passive energy renovations can reduce the energy demand of buildings. Thus, increasing the thermal insulation of the envelope has shown many improvements by reducing the energy loss in heating energy demand dominant areas. Consequently, national regulations of Member States, like the National Building Code (NBC) of Spain, require high thermal insulation levels for renovation processes. In addition, many high-performance labels demand thermal insulation above mandatory levels, like EnerPhit (the renovation label by Passivhaus). Nonetheless, renovations based on thermal insulation may affect the thermal comfort of buildings, depending on outdoor climatic conditions. The influence of adding thermal insulation on the possible increase in temperatures of residential spaces is still uncertain and requires analysis, given the risk of overheating. Based on this hypothesis, the objective of this study is to assess the influence of thermal insulation-based passive renovation on the overheating risk of residential spaces, focusing on the different climatic conditions of Spain. For this, the study evaluates the thermal conditions under different renovation scenarios on one residential multi-family archetype typical from the 70s and 80s, without any insulation. To this end, the research follows a three-staged methodology. First, the study identifies and defines one archetype, 12 climatic zones of Spain (following NBC) and 12 passive renovation strategies: four types of renovation strategies (façade exterior insulation, roof insulation, window replacement and the combination) in three efficiency levels (basic level, NBC required level and EnerPhit required level). Second, the study performs the Building Performance Simulation (BPS) of the parametric combination of all the climatic conditions and renovation strategies, analyzing the indoor operative temperature. Finally, the study evaluates the overheating hours based on the thermal comfort model by the Chartered Institution of Building Services Engineers (CIBSE). The evaluation shows the increase or decrease of overheating hours under different climatic conditions, renovation types and thermal insulation levels. These results indicate that the climatic zone is a key factor in assessing the overheating risk. Therefore, the study identifies the critical climatic zones of Spain with high overheating risk, which require more in depth analysis to avoid overheating on energy renovations.

Authors

Institutions

Publication Details

Journal
CONECT International Scientific Conference of Environmental and Climate Technologies
Published
2025-05-09
DOI
https://doi.org/10.7250/conect.2025.001
Primary Topic
Integrated Energy Systems Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Overheating Risk Assessment in Passive Energy Innovations in Spain

Markel Arbulu, Iñigo Rodríguez-Vidal, Xabat Oregi, Jorge Otaegi
CONECT International Scientific Conference of Environmental and Climate Technologies
Integrated Energy Systems Optimization
article

Overheating Risk Assessment in Passive Energy Innovations in Spain

Markel Arbulu, Iñigo Rodríguez-Vidal, Xabat Oregi, Jorge Otaegi
article en

Abstract

The regulations of the European Union (EU) demand the improvement of the energy efficiency of buildings. Following this, thermal insulation-based passive energy renovations can reduce the energy demand of buildings. Thus, increasing the thermal insulation of the envelope has shown many improvements by reducing the energy loss in heating energy demand dominant areas. Consequently, national regulations of Member States, like the National Building Code (NBC) of Spain, require high thermal insulation levels for renovation processes. In addition, many high-performance labels demand thermal insulation above mandatory levels, like EnerPhit (the renovation label by Passivhaus). Nonetheless, renovations based on thermal insulation may affect the thermal comfort of buildings, depending on outdoor climatic conditions. The influence of adding thermal insulation on the possible increase in temperatures of residential spaces is still uncertain and requires analysis, given the risk of overheating. Based on this hypothesis, the objective of this study is to assess the influence of thermal insulation-based passive renovation on the overheating risk of residential spaces, focusing on the different climatic conditions of Spain. For this, the study evaluates the thermal conditions under different renovation scenarios on one residential multi-family archetype typical from the 70s and 80s, without any insulation. To this end, the research follows a three-staged methodology. First, the study identifies and defines one archetype, 12 climatic zones of Spain (following NBC) and 12 passive renovation strategies: four types of renovation strategies (façade exterior insulation, roof insulation, window replacement and the combination) in three efficiency levels (basic level, NBC required level and EnerPhit required level). Second, the study performs the Building Performance Simulation (BPS) of the parametric combination of all the climatic conditions and renovation strategies, analyzing the indoor operative temperature. Finally, the study evaluates the overheating hours based on the thermal comfort model by the Chartered Institution of Building Services Engineers (CIBSE). The evaluation shows the increase or decrease of overheating hours under different climatic conditions, renovation types and thermal insulation levels. These results indicate that the climatic zone is a key factor in assessing the overheating risk. Therefore, the study identifies the critical climatic zones of Spain with high overheating risk, which require more in depth analysis to avoid overheating on energy renovations.

CONECT International Scientific Conference of Environmental and Climate Technologies
University of the Basque Country (ES)
Eusko Jaurlaritza, Euskal Herriko Unibertsitatea
Openalex Percentile: Top 92%
Integrated Energy Systems Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.