DEVELOPMENT AND VALIDATION OF A HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION (HPLC-PDA) BIOANALYTICAL METHOD FOR QUANTIFICATION OF IMATINIB MESYLATE IN HUMAN PLASMA

Objective: Chronic Myeloid Leukemia (CML) is a myeloproliferative neoplasm represented by the uncontrolled growth of myeloid cells at different stages of maturation. Imatinib Mesylate (IM) has set a new standard for treating CML and other cancers. Therefore, in order to do PK investigations and to periodically monitor imatinib, clinical laboratories need an analytical approach that is practically adaptable. The current analytical techniques for use laborious, time-consuming. The aim of this study was to develop and validate a fast and simple method for imatinib quantification in human plasma using High-Performance Liquid Chromatography (HPLC) using photodiode array detection. Methods: A mobile phase comprising potassium dihydrogen phosphate, methanol, and acetonitrile (30:35:35) with isocreatic programming was utilized to achieve the separation on an ODS C18 column (150×4.6 mm), 4µm column. The procedure consisted of simple protein precipitation with cold methanol extraction to obtain the maximum recovery from a 90 μl plasma sample. Results: The regression coefficient of 0.99 indicates that the procedure is linear in the range of 100 to 10,000 ng/ml. The total recovery of the approach under lower quality control was 102.45%, at middle-quality control 101.70%; and at higher quality control, it was 95.75%. Both accuracy and precision were within acceptable bounds. Conclusion: The quantification of imatinib levels in plasma of CML patients for Pharmacokinetic (PK) assessments and Therapeutic Drug Monitoring (TDM) necessitates the development and validation of an easy-to-use, effective, repeatable, and environmentally friendly analytical technique.

Authors

Institutions

Publication Details

Journal
International Journal of Applied Pharmaceutics
Published
2025-05-07
DOI
https://doi.org/10.22159/ijap.2025v17i3.52563
Primary Topic
Chronic Myeloid Leukemia Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

DEVELOPMENT AND VALIDATION OF A HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION (HPLC-PDA) BIOANALYTICAL METHOD FOR QUANTIFICATION OF IMATINIB MESYLATE IN HUMAN PLASMA

Surulivelrajan Mallayasamy, Sudheer Moorkoth, JAYA SHREE DILLI BATCHA, Ashutosh Gupta
International Journal of Applied Pharmaceutics
Chronic Myeloid Leukemia Treatments
article

DEVELOPMENT AND VALIDATION OF A HIGH-PERFORMANCE LIQUID CHROMATOGRAPHY WITH PHOTODIODE ARRAY DETECTION (HPLC-PDA) BIOANALYTICAL METHOD FOR QUANTIFICATION OF IMATINIB MESYLATE IN HUMAN PLASMA

Surulivelrajan Mallayasamy, Sudheer Moorkoth, JAYA SHREE DILLI BATCHA, Ashutosh Gupta
article en

Abstract

Objective: Chronic Myeloid Leukemia (CML) is a myeloproliferative neoplasm represented by the uncontrolled growth of myeloid cells at different stages of maturation. Imatinib Mesylate (IM) has set a new standard for treating CML and other cancers. Therefore, in order to do PK investigations and to periodically monitor imatinib, clinical laboratories need an analytical approach that is practically adaptable. The current analytical techniques for use laborious, time-consuming. The aim of this study was to develop and validate a fast and simple method for imatinib quantification in human plasma using High-Performance Liquid Chromatography (HPLC) using photodiode array detection. Methods: A mobile phase comprising potassium dihydrogen phosphate, methanol, and acetonitrile (30:35:35) with isocreatic programming was utilized to achieve the separation on an ODS C18 column (150×4.6 mm), 4µm column. The procedure consisted of simple protein precipitation with cold methanol extraction to obtain the maximum recovery from a 90 μl plasma sample. Results: The regression coefficient of 0.99 indicates that the procedure is linear in the range of 100 to 10,000 ng/ml. The total recovery of the approach under lower quality control was 102.45%, at middle-quality control 101.70%; and at higher quality control, it was 95.75%. Both accuracy and precision were within acceptable bounds. Conclusion: The quantification of imatinib levels in plasma of CML patients for Pharmacokinetic (PK) assessments and Therapeutic Drug Monitoring (TDM) necessitates the development and validation of an easy-to-use, effective, repeatable, and environmentally friendly analytical technique.

International Journal of Applied Pharmaceutics
Manipal Academy of Higher Education (IN)
Indian Council of Medical Research
Openalex Percentile: Top 87%
Chronic Myeloid Leukemia Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.