Implementasi Sensor PH-4502C dan Sensor Suhu DS18B20 Untuk Pemantauan Air Kolam Nila

In cultivating freshwater fish, especially tilapia, water quality is a very important factor and influences the survival of the fish being farmed. Several parameters that must be considered in improving the development of tilapia fish are temperature and pH of the water. So, a water quality monitoring system is needed to be able to assess these parameters simultaneously in one time (real time) to maintain the quality of fish cultivation. The system designed for monitoring water quality uses a pH sensor with a 4502C module and a Ds18b20 temperature sensor which is then processed using an Arduino Uno so that it can be seen on the LCD. The results of designing a temperature and pH monitoring system carried out for three days in tilapia ponds obtained an error rate in measuring the pH of pond water of 0.87% on the first day, 0.94% on the second day, and 0.79% on the third day. Apart from pH measurements, the pool temperature was measured using a comparison of two Ds18b20 temperature sensors with research results showing the highest temperature measurement at 12.00 WIB was 30.25˚C for three days.

Authors

Institutions

Publication Details

Journal
Electrician Jurnal Rekayasa dan Teknologi Elektro
Published
2025-05-09
DOI
https://doi.org/10.23960/elc.v19n2.2671
Primary Topic
Engineering and Technology Innovations
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Implementasi Sensor PH-4502C dan Sensor Suhu DS18B20 Untuk Pemantauan Air Kolam Nila

Novia Utami Putri, Ernando Rizki Dalimunthe, Wayan Rio Adi Pratama
Electrician Jurnal Rekayasa dan Teknologi Elektro
Engineering and Technology Innovations
article

Implementasi Sensor PH-4502C dan Sensor Suhu DS18B20 Untuk Pemantauan Air Kolam Nila

Novia Utami Putri, Ernando Rizki Dalimunthe, Wayan Rio Adi Pratama
article en

Abstract

In cultivating freshwater fish, especially tilapia, water quality is a very important factor and influences the survival of the fish being farmed. Several parameters that must be considered in improving the development of tilapia fish are temperature and pH of the water. So, a water quality monitoring system is needed to be able to assess these parameters simultaneously in one time (real time) to maintain the quality of fish cultivation. The system designed for monitoring water quality uses a pH sensor with a 4502C module and a Ds18b20 temperature sensor which is then processed using an Arduino Uno so that it can be seen on the LCD. The results of designing a temperature and pH monitoring system carried out for three days in tilapia ponds obtained an error rate in measuring the pH of pond water of 0.87% on the first day, 0.94% on the second day, and 0.79% on the third day. Apart from pH measurements, the pool temperature was measured using a comparison of two Ds18b20 temperature sensors with research results showing the highest temperature measurement at 12.00 WIB was 30.25˚C for three days.

Electrician Jurnal Rekayasa dan Teknologi ElektroVol. 19(2)
Universitas Teknokrat Indonesia (ID)
Openalex Percentile: Top 92%
Engineering and Technology Innovations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Implementasi Sensor PH-4502C dan Sensor Suhu DS18B20 Untuk Pemantauan Air Kolam Nila — Novia Utami Putri, Ernando Rizki Dalimunthe, et al. · Electrician Jurnal Rekayasa dan Teknologi Elektro (2025) | TGRS Research Map | TGRS