Finite element analysis of welded titanium bar and poly ether ether ketone bar in maxillary full arch splinted interim prosthesis

Full arch fixed provisional restorations are prone to fracture during function for several reasons. Those types of fractures during the healing period eliminate the cross-arch stabilization and disrupt stress distribution patterns. FEA (Finite Element Analysis) study was carried out using edentulous maxillary models where implants and other components were represented in three dimensional (3D) geometric models. Two 3D FEA models with six implants were used. Model TB: the implants were splinted with welded titanium bar; Model PB: the implants were splinted with PEEK (Poly Ether Ether Ketone) bar. An interim full arch PMMA (Poly methyl methacrylate) prosthesis was virtually designed for both models. Both models were subjected to vertical and oblique forces with a single force magnitude of 100 N. The amount of maximum equivalent Von-Mises stresses was calculated at the cervical part of the bone cylinder (marginal bone) and both frameworks. Under bilateral vertical loading, stresses were found to be comparable at the marginal bone between titanium and PEEK splinting. The PEEK framework had better and lower stress distribution than the titanium. While under unilateral oblique forces PEEK had better mechanical response on the marginal bone. And PEEK framework itself showed higher stresses than the titanium. The behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-09
DOI
https://doi.org/10.1038/s41598-025-99750-x
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Finite element analysis of welded titanium bar and poly ether ether ketone bar in maxillary full arch splinted interim prosthesis

Hany Ibrahim Eid, Latifah Mohamed, Reda Khalil Abdelrahman, Seid Mohammed et al.
Scientific Reports
Dental Implant Techniques and Outcomes
article

Finite element analysis of welded titanium bar and poly ether ether ketone bar in maxillary full arch splinted interim prosthesis

Hany Ibrahim Eid, Latifah Mohamed, Reda Khalil Abdelrahman, Seid Mohammed, Hebatallah Tarek Mohamed
article en

Abstract

Full arch fixed provisional restorations are prone to fracture during function for several reasons. Those types of fractures during the healing period eliminate the cross-arch stabilization and disrupt stress distribution patterns. FEA (Finite Element Analysis) study was carried out using edentulous maxillary models where implants and other components were represented in three dimensional (3D) geometric models. Two 3D FEA models with six implants were used. Model TB: the implants were splinted with welded titanium bar; Model PB: the implants were splinted with PEEK (Poly Ether Ether Ketone) bar. An interim full arch PMMA (Poly methyl methacrylate) prosthesis was virtually designed for both models. Both models were subjected to vertical and oblique forces with a single force magnitude of 100 N. The amount of maximum equivalent Von-Mises stresses was calculated at the cervical part of the bone cylinder (marginal bone) and both frameworks. Under bilateral vertical loading, stresses were found to be comparable at the marginal bone between titanium and PEEK splinting. The PEEK framework had better and lower stress distribution than the titanium. While under unilateral oblique forces PEEK had better mechanical response on the marginal bone. And PEEK framework itself showed higher stresses than the titanium. The behavior of PEEK and Titanium splints are comparable under the vertical bilateral load. On the contrary to the oblique load, where the stresses are higher within the PEEK splint that correspondingly transmit less stresses to the underlying structures. So, PEEK was found successful in regards to the pattern of stress distribution to both implants and marginal bone, but further studies are needed to confirm its effectiveness and broader applicability.

Scientific ReportsVol. 15(1)
Ain Shams University (EG), Cairo University (EG)
Ain Shams University
Life in Land
Openalex Percentile: Top 86%
Dental Implant Techniques and Outcomes
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.