Ratiometric Covalent Fluorescent Probes for Dynamic Super-Resolution Imaging of Mitochondrial HClO

Dynamic monitoring of hypochlorous acid (HClO) in mitochondria is crucial for elucidating the molecular pathogenesis of ferroptosis-related diseases. Super-resolution microscopy, which surpasses the optical diffraction limit, has emerged as a powerful tool for subcellular dynamic imaging. However, the lack of mitochondrial HClO fluorescent probes with high specificity, stable labeling, low environmental interference, and negligible spectral crosstalk presents a significant challenge for achieving dynamic super-resolution imaging. Here, we designed and screened a series of HClO fluorescent probes, ultimately obtaining a novel HClO probe, YM-P. The combination of a triphenylphosphine group and a chloroacetyl chloride group enables YM-P to achieve specific, covalent mitochondrial labeling, thereby overcoming off-target labeling during ferroptosis. The ratiometric fluorescence response of YM-P to HClO and its detection limit of as low as 35 nM allow it to resist interferences from environmental factors and ensure accurate detection of HClO. The ultralarge Stokes shift of 210 nm exhibited by YM-P also minimizes spectral crosstalk. Using YM-P, we achieved dynamic super-resolution imaging of mitochondrial HClO during ferroptosis. Notably, we observed for the first time that changes in mitochondrial cristae numbers precede alterations in HClO concentration, with an initial increase followed by a decrease, suggesting that mitochondrial cristae are more sensitive to the occurrence of ferroptosis than HClO concentration. This study provides a robust tool for dynamic monitoring of mitochondrial HClO during ferroptosis, as well as potential support for other mitochondrial HClO-related processes.

Authors

Institutions

Publication Details

Journal
ACS Sensors
Published
2025-05-09
DOI
https://doi.org/10.1021/acssensors.5c00640
Citations
10
Primary Topic
Nanoplatforms for cancer theranostics
Type
article
Field-Weighted Citation Impact
6.74

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ratiometric Covalent Fluorescent Probes for Dynamic Super-Resolution Imaging of Mitochondrial HClO

Peng Xu, Xinxin Duan, Meng Zhang, Yuhui Zhang et al.
10 citations
ACS Sensors
Nanoplatforms for cancer theranostics
6.74
article

Ratiometric Covalent Fluorescent Probes for Dynamic Super-Resolution Imaging of Mitochondrial HClO

Peng Xu, Xinxin Duan, Meng Zhang, Yuhui Zhang, Yunfei Wei, Huimin Feng, Xiangpeng Lin
article en
10 citations

Abstract

Dynamic monitoring of hypochlorous acid (HClO) in mitochondria is crucial for elucidating the molecular pathogenesis of ferroptosis-related diseases. Super-resolution microscopy, which surpasses the optical diffraction limit, has emerged as a powerful tool for subcellular dynamic imaging. However, the lack of mitochondrial HClO fluorescent probes with high specificity, stable labeling, low environmental interference, and negligible spectral crosstalk presents a significant challenge for achieving dynamic super-resolution imaging. Here, we designed and screened a series of HClO fluorescent probes, ultimately obtaining a novel HClO probe, YM-P. The combination of a triphenylphosphine group and a chloroacetyl chloride group enables YM-P to achieve specific, covalent mitochondrial labeling, thereby overcoming off-target labeling during ferroptosis. The ratiometric fluorescence response of YM-P to HClO and its detection limit of as low as 35 nM allow it to resist interferences from environmental factors and ensure accurate detection of HClO. The ultralarge Stokes shift of 210 nm exhibited by YM-P also minimizes spectral crosstalk. Using YM-P, we achieved dynamic super-resolution imaging of mitochondrial HClO during ferroptosis. Notably, we observed for the first time that changes in mitochondrial cristae numbers precede alterations in HClO concentration, with an initial increase followed by a decrease, suggesting that mitochondrial cristae are more sensitive to the occurrence of ferroptosis than HClO concentration. This study provides a robust tool for dynamic monitoring of mitochondrial HClO during ferroptosis, as well as potential support for other mitochondrial HClO-related processes.

ACS SensorsVol. 10(5)
Wuhan National Laboratory for Optoelectronics (CN), Huazhong University of Science and Technology (CN)
National Natural Science Foundation of China, China Postdoctoral Science Foundation, Huazhong University of Science and Technology, Wuhan National Laboratory for Optoelectronics, National Key Research and Development Program of China
Openalex Percentile: Top 3%
Nanoplatforms for cancer theranostics
6.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.