Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

The GAFCHROMIC LD-V1 radiochromic film is widely used in dosimetry because it can provide high-resolution two-dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low-energy range of mammography to the high-energy range of computed tomography. Net pixel value (NPV)-absorbed dose calibration curves for the GAFCHROMIC LD-V1 were generated using x-rays with effective energies of 18, 30, 50, and 80 keV to reflect those used in different diagnostic radiographic modalities. The film response was analyzed using calibration curves at each energy level. The coefficients of determination for the calibration curves at 18, 30, 50, and 80 keV were 0.9992, 0.9997, 0.9999, and 0.9976, respectively. The pixel value change at 30 keV was the largest and most sensitive, while the smallest change in pixel value and lowest sensitivity were noted at 18 keV. Because the energy dependence of the GAFCHROMIC LD-V1 is significant below 18 keV and above 80 keV, it is necessary to establish an appropriate NPV-absorbed dose calibration curve for energies below 18 keV and consider the possibility of underestimating the dose at energies above 80 keV.

Authors

Institutions

Publication Details

Journal
Journal of Applied Clinical Medical Physics
Published
2025-05-09
DOI
https://doi.org/10.1002/acm2.70117
Citations
2
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
2.72
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

Hidetoshi Yatake, Nobuyoshi Tanki, Shinnosuke Nishihara, Toshizo Katsuda et al.
2 citations
Journal of Applied Clinical Medical Physics
Radiation Dose and Imaging
2.72
article

Energy dependence of the GAFCHROMIC LD‐V1 in the diagnostic radiographic modalities

Hidetoshi Yatake, Nobuyoshi Tanki, Shinnosuke Nishihara, Toshizo Katsuda, Takuya Akagawa, Tomoyuki Hasuo, Tatsuhiro Gotanda, Shinya Imai, Yasuyuki Kawaji, K Matsuura
article en
2 citations

Abstract

The GAFCHROMIC LD-V1 radiochromic film is widely used in dosimetry because it can provide high-resolution two-dimensional dose distributions without processing. This study aimed to evaluate the response characteristics at different effective energies, from the low-energy range of mammography to the high-energy range of computed tomography. Net pixel value (NPV)-absorbed dose calibration curves for the GAFCHROMIC LD-V1 were generated using x-rays with effective energies of 18, 30, 50, and 80 keV to reflect those used in different diagnostic radiographic modalities. The film response was analyzed using calibration curves at each energy level. The coefficients of determination for the calibration curves at 18, 30, 50, and 80 keV were 0.9992, 0.9997, 0.9999, and 0.9976, respectively. The pixel value change at 30 keV was the largest and most sensitive, while the smallest change in pixel value and lowest sensitivity were noted at 18 keV. Because the energy dependence of the GAFCHROMIC LD-V1 is significant below 18 keV and above 80 keV, it is necessary to establish an appropriate NPV-absorbed dose calibration curve for energies below 18 keV and consider the possibility of underestimating the dose at energies above 80 keV.

Journal of Applied Clinical Medical PhysicsVol. 26(7)
Morinomiya University of Medical Sciences (JP), Junshin Gakuen University (JP), Tokushima Red Cross Hospital (JP), Shizuoka Medical Center (JP), Takarazuka City Hospital (JP), Kawasaki University of Medical Welfare (JP)
Affordable and clean energy
Openalex Percentile: Top 11%
Radiation Dose and Imaging
2.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.