A Simulation of the Biomechanical Behavior of Orthodontic Miniscrews for Infrazygomatic Anchorage: An In Vitro Study

Background: This study aims to investigate the biomechanical characteristics of orthodontic miniscrews manufactured for use in infrazygomatic crests. Methods: This study analyzed the Zygomatic Spider Screw (HDC, Thiene, Italy), considering four variables: length, insertion angle, insertion depth, support thickness. Twenty-two configurations were tested on 66 miniscrews, all with a diameter of 2 mm, and were inserted into D1 bone-like supports. After compression tests, the deformation angles and linear distances between the tips of the miniscrews were measured. Results: Power analysis showed 99% power for the deformation angles and linear distance. The ICC indicated the good repeatability of the results, with values above 0.70. The mean maximum load values ranged from 21.5 N to 228.8 N, while the mean deformations ranged from 0.45 mm to 2.26 mm. Miniscrews with greater insertion depths (6 and 8 mm) exhibited approximately twice the average deformation (1.5 mm) compared to those inserted at 2 and 4 mm (0.71 mm). It was noted that miniscrews with higher deformation and a lower applied load were those with a working part length of 10 mm and an insertion depth of 2 mm, while those with lower deformation and a better load-bearing capacity were those with a working part length of 6 mm that were fully inserted into the bone support. Conclusions: The miniscrew design and insertion depth significantly affect biomechanical properties. It is advisable to maximize the insertion depth and minimize the distance between the support and the point of force application. The insertion angle did not prove to be a determining factor in the load.

Authors

Institutions

Publication Details

Journal
Sci
Published
2025-05-09
DOI
https://doi.org/10.3390/sci7020064
Primary Topic
Orthodontics and Dentofacial Orthopedics
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simulation of the Biomechanical Behavior of Orthodontic Miniscrews for Infrazygomatic Anchorage: An In Vitro Study

Mario Palone, Filippo Pepe, Luca Lombardo, Francesca Cremonini et al.
Sci
Orthodontics and Dentofacial Orthopedics
article

A Simulation of the Biomechanical Behavior of Orthodontic Miniscrews for Infrazygomatic Anchorage: An In Vitro Study

Mario Palone, Filippo Pepe, Luca Lombardo, Francesca Cremonini, Niki Arveda, Marta Calza, Davide Tucci
article en

Abstract

Background: This study aims to investigate the biomechanical characteristics of orthodontic miniscrews manufactured for use in infrazygomatic crests. Methods: This study analyzed the Zygomatic Spider Screw (HDC, Thiene, Italy), considering four variables: length, insertion angle, insertion depth, support thickness. Twenty-two configurations were tested on 66 miniscrews, all with a diameter of 2 mm, and were inserted into D1 bone-like supports. After compression tests, the deformation angles and linear distances between the tips of the miniscrews were measured. Results: Power analysis showed 99% power for the deformation angles and linear distance. The ICC indicated the good repeatability of the results, with values above 0.70. The mean maximum load values ranged from 21.5 N to 228.8 N, while the mean deformations ranged from 0.45 mm to 2.26 mm. Miniscrews with greater insertion depths (6 and 8 mm) exhibited approximately twice the average deformation (1.5 mm) compared to those inserted at 2 and 4 mm (0.71 mm). It was noted that miniscrews with higher deformation and a lower applied load were those with a working part length of 10 mm and an insertion depth of 2 mm, while those with lower deformation and a better load-bearing capacity were those with a working part length of 6 mm that were fully inserted into the bone support. Conclusions: The miniscrew design and insertion depth significantly affect biomechanical properties. It is advisable to maximize the insertion depth and minimize the distance between the support and the point of force application. The insertion angle did not prove to be a determining factor in the load.

SciVol. 7(2)
University of Ferrara (IT)
Openalex Percentile: Top 89%
Orthodontics and Dentofacial Orthopedics
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Simulation of the Biomechanical Behavior of Orthodontic Miniscrews for Infrazygomatic Anchorage: An In Vitro Study — Mario Palone, Filippo Pepe, et al. · Sci (2025) | TGRS Research Map | TGRS