Hetero-core fiber optic pH sensor coated with Au nanoparticles immobilized in pH-sensitive polymer multilayers

In this paper, we have conducted a comparative study between hetero-core optical fiber localized surface plasmon resonance-based pH sensors that have been coated with a combination of different pH-sensitive polymers using the self-assembling layer-by-layer technique in the acidic pH range of 4.0-6.0. We have found that the pH response of the sensors in the given pH range increased with an increase in the number of self-assembled bilayers, and have concluded that the Poly-L-Lysine, Poly Acrylic Acid pair containing 30 layers had the highest optical loss change of 0.315 dB in response to pH change in the range of 4.0-5.5 at 650 nm wavelength out of all the other combinations.

Authors

Institutions

Publication Details

Journal
Optics Express
Published
2025-05-09
DOI
https://doi.org/10.1364/oe.559509
Citations
1
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
0.74
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hetero-core fiber optic pH sensor coated with Au nanoparticles immobilized in pH-sensitive polymer multilayers

Kazuhiro Watanabe, Atsushi Seki, Deepro Banerjee, Michiko Nishiyama
1 citations
Optics Express
Analytical Chemistry and Sensors
0.74
article

Hetero-core fiber optic pH sensor coated with Au nanoparticles immobilized in pH-sensitive polymer multilayers

Kazuhiro Watanabe, Atsushi Seki, Deepro Banerjee, Michiko Nishiyama
article en
1 citations

Abstract

In this paper, we have conducted a comparative study between hetero-core optical fiber localized surface plasmon resonance-based pH sensors that have been coated with a combination of different pH-sensitive polymers using the self-assembling layer-by-layer technique in the acidic pH range of 4.0-6.0. We have found that the pH response of the sensors in the given pH range increased with an increase in the number of self-assembled bilayers, and have concluded that the Poly-L-Lysine, Poly Acrylic Acid pair containing 30 layers had the highest optical loss change of 0.315 dB in response to pH change in the range of 4.0-5.5 at 650 nm wavelength out of all the other combinations.

Optics ExpressVol. 33(11)
Core Laboratories (United States) (US)
Openalex Percentile: Top 34%
Analytical Chemistry and Sensors
0.74
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.