Microfluidics integrated with inkjet-printed SERS substrate for in-operando reaction kinetic monitoring

The study of kinetics and reaction mechanisms is fundamental in the chemical sciences, and various optical, magnetic, and electrochemical techniques are used today. Microfluidics offer s the unique opportunity of achieving accurate control over the reagent mixture, but appropriate strategies must be incorporated to track the reactive environment. It is herein presented the implementation of the kinetic monitoring of a biomimetic reaction of high interest within a microfluidic device by means of the product’s SERS signals. The chip involves an aluminum foil inkjet-printed with a gold nanoparticle (AuNP) ink, resulting in a rough film of 200 nm in thickness. The same is patterned according to microfluidic side walls obtained from a 500 µm brass foil, closed at the top with a glass coverslip. The result is a microfluidic device in which the entire length of the channel serves as an efficient SERS substrate, which is used to monitor laminar flows and species diffusion, as well as the second-order reaction kinetic constant between the cofactor pyridoxal 5’-phosphate (PLP) and a modified aniline. The success of the presented approach constitutes a first prototype of a continuous SERS monitoring of reactive components within microfluidic chips, paving the way for a variety of other conditions and configurations. • Inkjet-printed AuNP thin film in a microfluidic device is used for imaging reaction kinetic • Diffusion and laminar flow analysis done through SERS signals with spatial resolution • A complex system is studied at the time-domain through its spatial projection • Use of the microfluidic device solves the problem of SERS memory effect

Authors

Institutions

Publication Details

Journal
Sensors and Actuators B Chemical
Published
2025-05-09
DOI
https://doi.org/10.1016/j.snb.2025.137950
Citations
4
Primary Topic
Innovative Microfluidic and Catalytic Techniques Innovation
Type
article
Field-Weighted Citation Impact
2.70
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Microfluidics integrated with inkjet-printed SERS substrate for in-operando reaction kinetic monitoring

Daniele Filippi, Tommaso Marchetti, Luca Gabrielli, Lucio Litti et al.
4 citations
Sensors and Actuators B Chemical
Innovative Microfluidic and Catalytic Techniques Innovation
2.70
article

Microfluidics integrated with inkjet-printed SERS substrate for in-operando reaction kinetic monitoring

Daniele Filippi, Tommaso Marchetti, Luca Gabrielli, Lucio Litti, Davide Ferraro, Alessio Meggiolaro, Moreno Meneghetti, Francesco Cardoni, Anna Mercedi, Francesca Toffanello
article en
4 citations

Abstract

The study of kinetics and reaction mechanisms is fundamental in the chemical sciences, and various optical, magnetic, and electrochemical techniques are used today. Microfluidics offer s the unique opportunity of achieving accurate control over the reagent mixture, but appropriate strategies must be incorporated to track the reactive environment. It is herein presented the implementation of the kinetic monitoring of a biomimetic reaction of high interest within a microfluidic device by means of the product’s SERS signals. The chip involves an aluminum foil inkjet-printed with a gold nanoparticle (AuNP) ink, resulting in a rough film of 200 nm in thickness. The same is patterned according to microfluidic side walls obtained from a 500 µm brass foil, closed at the top with a glass coverslip. The result is a microfluidic device in which the entire length of the channel serves as an efficient SERS substrate, which is used to monitor laminar flows and species diffusion, as well as the second-order reaction kinetic constant between the cofactor pyridoxal 5’-phosphate (PLP) and a modified aniline. The success of the presented approach constitutes a first prototype of a continuous SERS monitoring of reactive components within microfluidic chips, paving the way for a variety of other conditions and configurations. • Inkjet-printed AuNP thin film in a microfluidic device is used for imaging reaction kinetic • Diffusion and laminar flow analysis done through SERS signals with spatial resolution • A complex system is studied at the time-domain through its spatial projection • Use of the microfluidic device solves the problem of SERS memory effect

Sensors and Actuators B ChemicalVol. 440
University of Padua (IT)
Affordable and clean energy
Openalex Percentile: Top 10%
Innovative Microfluidic and Catalytic Techniques Innovation
2.70
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.