Comparison of the Influences of Fresh and Corroded Carbon Steels on the Decay Law of Sodium Hypochlorite in Reclaimed Water

Sodium hypochlorite is a commonly used disinfectant in reclaimed water, and the decay law of its free chlorine directly affects the disinfection effect and the safety of reclaimed water. Currently, most of the decay studies have been carried out on the temperature, pH value, and concentration of organic matter in water, without fully considering the differences between fresh and corroded pipeline materials and their effects. This study aims to compare the influences of fresh and corroded carbon steels on the decay law of sodium hypochlorite through dynamic reaction devices and static flask experiments, based on simulations using uncorroded and pre-corroded carbon steel hanging plates. The effects of Fe⁰ and corrosion products on sodium hypochlorite decay are investigated to provide data support for disinfection strategies in reclaimed water distribution networks. By integrating DPD spectrophotometry, ATP detection, XRD analysis, and corrosion weight loss analysis, the microbial control efficacy and corrosion of sodium hypochlorite under the effects of fresh and corroded carbon steels are compared. The differences in decay kinetics are quantified using the restricted first-order decay model, and the dominant mechanisms of sodium hypochlorite consumption that cause differences in the effectiveness of the action are explored. The influences of fresh and corroded carbon steels on the decay are evaluated. Additionally, the percentages of consumption are also analyzed. The results show that in order to effectively kill microorganisms while reducing corrosion, it is recommended to add sodium hypochlorite under simulated conditions for fresh and corroded carbon steels to achieve free chlorine concentrations of 5 mg/L and 9 mg/L in the water, respectively. The effective control time of sodium chlorate on microorganisms in the bulk of the water under the fresh carbon steel conditions can be maintained for up to 48 h. However, under the corroded carbon steel conditions, the activity of microorganisms in the bulk of the water is relatively high, with an effective action time of only 8 h. The decay coefficient of sodium chlorate under the corroded carbon steel conditions is 2.61~6.94 times that of the fresh carbon steel. The additional average consumption of sodium hypochlorite under the corroded carbon steel conditions is 13.91~26.57% compared to the fresh carbon steel. Both Fe0 and corrosion products accelerate the decay of sodium hypochlorite in the initial stage, with an average consumption increase rate of 18.9% for Fe0 and 17.4% for corrosion products. The bulk decay coefficient is 0.073 h−1, and the wall decay coefficient represented by Fe0 is 0.204 h−1, which is higher than the wall decay coefficient represented by corrosion products, which is 0.077 h−1.

Authors

Institutions

Publication Details

Journal
Water
Published
2025-05-09
DOI
https://doi.org/10.3390/w17101428
Primary Topic
Corrosion Behavior and Inhibition
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of the Influences of Fresh and Corroded Carbon Steels on the Decay Law of Sodium Hypochlorite in Reclaimed Water

Ping Xu, Bo Liu, Xuan Wang
Water
Corrosion Behavior and Inhibition
article

Comparison of the Influences of Fresh and Corroded Carbon Steels on the Decay Law of Sodium Hypochlorite in Reclaimed Water

Ping Xu, Bo Liu, Xuan Wang
article en

Abstract

Sodium hypochlorite is a commonly used disinfectant in reclaimed water, and the decay law of its free chlorine directly affects the disinfection effect and the safety of reclaimed water. Currently, most of the decay studies have been carried out on the temperature, pH value, and concentration of organic matter in water, without fully considering the differences between fresh and corroded pipeline materials and their effects. This study aims to compare the influences of fresh and corroded carbon steels on the decay law of sodium hypochlorite through dynamic reaction devices and static flask experiments, based on simulations using uncorroded and pre-corroded carbon steel hanging plates. The effects of Fe⁰ and corrosion products on sodium hypochlorite decay are investigated to provide data support for disinfection strategies in reclaimed water distribution networks. By integrating DPD spectrophotometry, ATP detection, XRD analysis, and corrosion weight loss analysis, the microbial control efficacy and corrosion of sodium hypochlorite under the effects of fresh and corroded carbon steels are compared. The differences in decay kinetics are quantified using the restricted first-order decay model, and the dominant mechanisms of sodium hypochlorite consumption that cause differences in the effectiveness of the action are explored. The influences of fresh and corroded carbon steels on the decay are evaluated. Additionally, the percentages of consumption are also analyzed. The results show that in order to effectively kill microorganisms while reducing corrosion, it is recommended to add sodium hypochlorite under simulated conditions for fresh and corroded carbon steels to achieve free chlorine concentrations of 5 mg/L and 9 mg/L in the water, respectively. The effective control time of sodium chlorate on microorganisms in the bulk of the water under the fresh carbon steel conditions can be maintained for up to 48 h. However, under the corroded carbon steel conditions, the activity of microorganisms in the bulk of the water is relatively high, with an effective action time of only 8 h. The decay coefficient of sodium chlorate under the corroded carbon steel conditions is 2.61~6.94 times that of the fresh carbon steel. The additional average consumption of sodium hypochlorite under the corroded carbon steel conditions is 13.91~26.57% compared to the fresh carbon steel. Both Fe0 and corrosion products accelerate the decay of sodium hypochlorite in the initial stage, with an average consumption increase rate of 18.9% for Fe0 and 17.4% for corrosion products. The bulk decay coefficient is 0.073 h−1, and the wall decay coefficient represented by Fe0 is 0.204 h−1, which is higher than the wall decay coefficient represented by corrosion products, which is 0.077 h−1.

WaterVol. 17(10)
China State Construction Engineering (China) (CN), Beijing University of Civil Engineering and Architecture (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 93%
Corrosion Behavior and Inhibition
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.