Custom-Designed Portable Potentiostat and Indirect Cyclic Voltammetry Index Analysis for Rapid Pesticide Detection Using Molecularly Imprinted Polymer Sensors

Water pesticide contamination represents a major threat to ecological systems and public health, particularly in agricultural regions. Although conventional detection methods such as liquid chromatography and electrochemical analysis are highly accurate, they are expensive, require skilled operators, and cannot provide real-time results. This study developed a portable miniaturized electrochemical analysis platform based on cyclic voltammetry (CV) for rapid pesticide detection. The platform was compared with a commercial electrochemical analyzer and yielded similar performance in detecting chlorpyrifos at different concentrations. When ultrapure water was used as the background solution, the total area under the CV curve exhibited a linear correlation (<i>R</i><sup>2</sup> = 0.89) with the pesticide concentration, indicating its potential as a characteristic index. When molecularly imprinted polymers were added, the platform achieved a limit of detection of 50 ppm, with the area under the CV curve maintaining a logarithmic linear relationship (<i>R</i><sup>2</sup> = 0.98) with the pesticide concentration. These findings confirm the total area under the CV curve as the most reliable characteristic index for pesticide quantification. Overall, the proposed platform offers portability, straightforward operation, cost-effectiveness, and expandability, making it promising for on-site environmental monitoring. By incorporating GPS functionality, the platform can provide real-time pesticide concentration mapping, supporting its use in precision agriculture and water quality management.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-05-09
DOI
https://doi.org/10.3390/s25102999
Citations
2
Primary Topic
Analytical Chemistry and Sensors
Type
article
Field-Weighted Citation Impact
1.47

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Custom-Designed Portable Potentiostat and Indirect Cyclic Voltammetry Index Analysis for Rapid Pesticide Detection Using Molecularly Imprinted Polymer Sensors

Chen-Ju Lee, Liang-Chieh Chao, Min-Wei Hung, Hsin‐Yi Tsai et al.
2 citations
Sensors
Analytical Chemistry and Sensors
1.47
article

Custom-Designed Portable Potentiostat and Indirect Cyclic Voltammetry Index Analysis for Rapid Pesticide Detection Using Molecularly Imprinted Polymer Sensors

Chen-Ju Lee, Liang-Chieh Chao, Min-Wei Hung, Hsin‐Yi Tsai, Chanchana Thanachayanont, Kuo‐Cheng Huang, Yu–Hsuan Lin
article en
2 citations

Abstract

Water pesticide contamination represents a major threat to ecological systems and public health, particularly in agricultural regions. Although conventional detection methods such as liquid chromatography and electrochemical analysis are highly accurate, they are expensive, require skilled operators, and cannot provide real-time results. This study developed a portable miniaturized electrochemical analysis platform based on cyclic voltammetry (CV) for rapid pesticide detection. The platform was compared with a commercial electrochemical analyzer and yielded similar performance in detecting chlorpyrifos at different concentrations. When ultrapure water was used as the background solution, the total area under the CV curve exhibited a linear correlation (<i>R</i><sup>2</sup> = 0.89) with the pesticide concentration, indicating its potential as a characteristic index. When molecularly imprinted polymers were added, the platform achieved a limit of detection of 50 ppm, with the area under the CV curve maintaining a logarithmic linear relationship (<i>R</i><sup>2</sup> = 0.98) with the pesticide concentration. These findings confirm the total area under the CV curve as the most reliable characteristic index for pesticide quantification. Overall, the proposed platform offers portability, straightforward operation, cost-effectiveness, and expandability, making it promising for on-site environmental monitoring. By incorporating GPS functionality, the platform can provide real-time pesticide concentration mapping, supporting its use in precision agriculture and water quality management.

SensorsVol. 25(10)
Thailand National Metal and Materials Technology Center (TH), National Institutes of Applied Research (TW)
National Tsing Hua University, National Science and Technology Council
Clean water and sanitation
Openalex Percentile: Top 20%
Analytical Chemistry and Sensors
1.47
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.