The Potential Morphological Stenosis Pattern of the Arcuate Foramen

<b>Background</b>: The arcuate foramen (AF), an osseous foramen, is probably formatted from the ossification of the posterior atlanto-occipital membrane. When this morphologically ossified variant exists, it encloses the vertebral artery (VA) third segment (V3). This close relationship may cause compression to the VA with concomitant vertebrobasilar insufficiency, vertigo, headaches, or neck pain. In the published literature, no studies investigate the abovementioned potential compression pattern. The present study examines the AF ossification pattern (complete or partial type) and the variable VA diameter at the atlantal part (V3), concluding a potential risk for VA compression after correlating the relative diameters (AF and VA diameters). <b>Materials and Methods</b>: One hundred and fifty dried first cervical vertebrae (atlases) and one hundred fifty computed tomography (CT) scans were obtained for the present study. The presence of a complete or incomplete AF was evaluated, and when present, its diameter was measured. To correlate these findings with the vessel, 50 computed tomography angiographies (without AF presence) were obtained to measure the V3 segment diameter. <b>Results</b>: Out of the total 600 (<i>N</i> = 600) sides, 111 sides had incomplete AF (18.2%), and 67 sides had complete AF (11.1%). The AF mean diameter was 6.41 (1.12) mm. The diameter of the V3 segment ranged between 5.0 and 6.0 mm; therefore, three morphological stenosis patterns were identified. A low risk of compression (over 6.0 mm) was identified in 61.2% (<i>N</i> = 109 sides), a moderate risk (between 5.0-6.0 mm) was observed in 29.2% (<i>N</i> = 52 sides), and a high risk (under 5.0 mm) was recorded in 9.6% (<i>N</i> = 17 sides). There was no statistically significant correlation regarding sexes and age for the potential compression patterns. <b>Conclusions</b>: The present study revealed the morphological stenosis pattern of the AF to the V3 segment. The variation had a high risk of compression to the vessel in 9.6% of sides, indicating that it is not infrequent. Knowledge of these details is essential for clinicians when investigating vertebrobasilar insufficiency.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-05-09
DOI
https://doi.org/10.3390/diagnostics15101203
Citations
3
Primary Topic
Spinal Fractures and Fixation Techniques
Type
article
Field-Weighted Citation Impact
6.02
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Potential Morphological Stenosis Pattern of the Arcuate Foramen

George A. Tsakotos, Fabrice Duparc, Ioannis Paschopoulos, Răzvan Costin Tudose et al.
3 citations
Diagnostics
Spinal Fractures and Fixation Techniques
6.02
article

The Potential Morphological Stenosis Pattern of the Arcuate Foramen

George A. Tsakotos, Fabrice Duparc, Ioannis Paschopoulos, Răzvan Costin Tudose, Panagiotis Papadopoulos-Manolarakis, Maria Piagkou, George Triantafyllou, Mugurel Constantin Rusu, Oana Toader, Fotis Demetriou
article en
3 citations

Abstract

<b>Background</b>: The arcuate foramen (AF), an osseous foramen, is probably formatted from the ossification of the posterior atlanto-occipital membrane. When this morphologically ossified variant exists, it encloses the vertebral artery (VA) third segment (V3). This close relationship may cause compression to the VA with concomitant vertebrobasilar insufficiency, vertigo, headaches, or neck pain. In the published literature, no studies investigate the abovementioned potential compression pattern. The present study examines the AF ossification pattern (complete or partial type) and the variable VA diameter at the atlantal part (V3), concluding a potential risk for VA compression after correlating the relative diameters (AF and VA diameters). <b>Materials and Methods</b>: One hundred and fifty dried first cervical vertebrae (atlases) and one hundred fifty computed tomography (CT) scans were obtained for the present study. The presence of a complete or incomplete AF was evaluated, and when present, its diameter was measured. To correlate these findings with the vessel, 50 computed tomography angiographies (without AF presence) were obtained to measure the V3 segment diameter. <b>Results</b>: Out of the total 600 (<i>N</i> = 600) sides, 111 sides had incomplete AF (18.2%), and 67 sides had complete AF (11.1%). The AF mean diameter was 6.41 (1.12) mm. The diameter of the V3 segment ranged between 5.0 and 6.0 mm; therefore, three morphological stenosis patterns were identified. A low risk of compression (over 6.0 mm) was identified in 61.2% (<i>N</i> = 109 sides), a moderate risk (between 5.0-6.0 mm) was observed in 29.2% (<i>N</i> = 52 sides), and a high risk (under 5.0 mm) was recorded in 9.6% (<i>N</i> = 17 sides). There was no statistically significant correlation regarding sexes and age for the potential compression patterns. <b>Conclusions</b>: The present study revealed the morphological stenosis pattern of the AF to the V3 segment. The variation had a high risk of compression to the vessel in 9.6% of sides, indicating that it is not infrequent. Knowledge of these details is essential for clinicians when investigating vertebrobasilar insufficiency.

DiagnosticsVol. 15(10)
Carol Davila University of Medicine and Pharmacy (RO), National and Kapodistrian University of Athens (GR), General Hospital of Nikea (GR), Université de Rouen Normandie (FR)
Life below water
Openalex Percentile: Top 4%
Spinal Fractures and Fixation Techniques
6.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.