Redundancy alarm algorithm for hidden danger points in transmission lines under unmanned aerial vehicle three-dimensional ranging

In the process of inspecting transmission lines, it is difficult to accurately identify and eliminate redundant hidden points that are close or overlapping in spatial location when facing different scales and complex power grids. Therefore, a redundant alarm algorithm for hidden danger points in transmission lines based on unmanned aerial vehicle 3D ranging technology is proposed. Extract representative point information from the original drone 3D ranging point cloud data and write it into a new file in LAS format. Simplifying point cloud data through voxel grid partitioning can effectively reduce redundant information. Process and match point cloud data to obtain hidden points. Take three steps to eliminate redundancy: spatial location, time interval, and type merging. Based on the degree of threat, compare the shape of the cluster with known hidden point shape templates to determine whether the cluster is a hidden point. The experimental results show that the proposed method has a high processing efficiency, above 0.9, and can maintain an accuracy of above 0.8.

Authors

Institutions

Publication Details

Published
2025-05-09
DOI
https://doi.org/10.1117/12.3067307
Primary Topic
Power Line Inspection Robots
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Redundancy alarm algorithm for hidden danger points in transmission lines under unmanned aerial vehicle three-dimensional ranging

Yizhao Zhang, Qianyong Lv, Huan Huang, Diao Zhou
Power Line Inspection Robots
article

Redundancy alarm algorithm for hidden danger points in transmission lines under unmanned aerial vehicle three-dimensional ranging

Yizhao Zhang, Qianyong Lv, Huan Huang, Diao Zhou
article en

Abstract

In the process of inspecting transmission lines, it is difficult to accurately identify and eliminate redundant hidden points that are close or overlapping in spatial location when facing different scales and complex power grids. Therefore, a redundant alarm algorithm for hidden danger points in transmission lines based on unmanned aerial vehicle 3D ranging technology is proposed. Extract representative point information from the original drone 3D ranging point cloud data and write it into a new file in LAS format. Simplifying point cloud data through voxel grid partitioning can effectively reduce redundant information. Process and match point cloud data to obtain hidden points. Take three steps to eliminate redundancy: spatial location, time interval, and type merging. Based on the degree of threat, compare the shape of the cluster with known hidden point shape templates to determine whether the cluster is a hidden point. The experimental results show that the proposed method has a high processing efficiency, above 0.9, and can maintain an accuracy of above 0.8.

Guizhou Electric Power Design and Research Institute (CN)
Openalex Percentile: Top 90%
Power Line Inspection Robots
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.