EPA LEAF Testing of Ultra-Lightweight Foamed Glass Aggregate to Support Vapor Barrier Applications on Ponds and Lagoons

Foamed glass aggregate (FGA) was characterized to evaluate its potential to serve as a vapor barrier on various water bodies [water supply reservoirs, industrial lagoons, acid mine drainage (AMD) ponds, etc.] Specifically, the FGA was tested for its total metal content for the target analyte list (TAL) metals and the leaching of the same by Environmental Protection Agency (EPA) Methods 1311 [Toxicity Characteristic Leaching Procedure (TCLP], 1312 [Synthetic Precipitation Leaching Procedure (SPLP)], 1313 (Leaching as a function of pH), and 1316 [Leaching as a function of the liquid-to-solid (L/S)] ratio. The commercially available FGA ranges from 25 to 38 mm in diameter and is oversized (OS) compared to the maximum particle size allowed by the TCLP/SPLP test (9.5 mm) and EPA 1313/1316 (5 mm). As such, each leaching test was run on a particle size-reduced FGA (<9.5 mm), and the contact period during EPA 1313/1316 tests was extended from the method maximum of 3 to 7 days to promote equilibration. Additionally, a secondary EPA 1313 test was performed with sulfuric acid to evaluate conditions relevant to mining/industry conditions, and higher L/S ratios of 20, 50, and 100 were added to EPA 1316 to simulate pond/lagoon-type conditions. The FGA was found to be nonhazardous and passed the most stringent regional clean-fill requirements where it was produced. Leaching by EPA 1316 with L/S ≥ 20 satisfied the EPA drinking water standards except for arsenic; however, this was attributed to the increased FGA surface area created by self-abrasion during the end-over-end tumbling extraction, which produced 17 wt% fines. Two additional 7-day EPA 1316 extractions performed using the OS FGA at L/S 10 and 100 in a modified extractor with a magnetic stirrer (no self-abrasion) leached no heavy metals above the method detection limits, only common soil elements. For an EPA 1313 test (L/S 10) on the OS FGA under strongly sulfuric acid conditions (pH < 1.5), 9 of 15 heavy metal (Sb, As, Ag, Be, Cd, Mo, Se, Tl, V) concentrations were all below their reporting limits for drinking water, and all other TAL metals (including common soil elements) were substantially below representative AMD conditions.

Authors

Institutions

Publication Details

Journal
Journal of Hazardous Toxic and Radioactive Waste
Published
2025-05-09
DOI
https://doi.org/10.1061/jhtrbp.hzeng-1484
Primary Topic
Urban Stormwater Management Solutions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

EPA LEAF Testing of Ultra-Lightweight Foamed Glass Aggregate to Support Vapor Barrier Applications on Ponds and Lagoons

A. Filshill, Dusty R. V. Berggren, Dennis G. Grubb, Ester K. Helbling
4 links
Journal of Hazardous Toxic and Radioactive Waste
Urban Stormwater Management Solutions
article

EPA LEAF Testing of Ultra-Lightweight Foamed Glass Aggregate to Support Vapor Barrier Applications on Ponds and Lagoons

A. Filshill, Dusty R. V. Berggren, Dennis G. Grubb, Ester K. Helbling
article en

Abstract

Foamed glass aggregate (FGA) was characterized to evaluate its potential to serve as a vapor barrier on various water bodies [water supply reservoirs, industrial lagoons, acid mine drainage (AMD) ponds, etc.] Specifically, the FGA was tested for its total metal content for the target analyte list (TAL) metals and the leaching of the same by Environmental Protection Agency (EPA) Methods 1311 [Toxicity Characteristic Leaching Procedure (TCLP], 1312 [Synthetic Precipitation Leaching Procedure (SPLP)], 1313 (Leaching as a function of pH), and 1316 [Leaching as a function of the liquid-to-solid (L/S)] ratio. The commercially available FGA ranges from 25 to 38 mm in diameter and is oversized (OS) compared to the maximum particle size allowed by the TCLP/SPLP test (9.5 mm) and EPA 1313/1316 (5 mm). As such, each leaching test was run on a particle size-reduced FGA (<9.5 mm), and the contact period during EPA 1313/1316 tests was extended from the method maximum of 3 to 7 days to promote equilibration. Additionally, a secondary EPA 1313 test was performed with sulfuric acid to evaluate conditions relevant to mining/industry conditions, and higher L/S ratios of 20, 50, and 100 were added to EPA 1316 to simulate pond/lagoon-type conditions. The FGA was found to be nonhazardous and passed the most stringent regional clean-fill requirements where it was produced. Leaching by EPA 1316 with L/S ≥ 20 satisfied the EPA drinking water standards except for arsenic; however, this was attributed to the increased FGA surface area created by self-abrasion during the end-over-end tumbling extraction, which produced 17 wt% fines. Two additional 7-day EPA 1316 extractions performed using the OS FGA at L/S 10 and 100 in a modified extractor with a magnetic stirrer (no self-abrasion) leached no heavy metals above the method detection limits, only common soil elements. For an EPA 1313 test (L/S 10) on the OS FGA under strongly sulfuric acid conditions (pH < 1.5), 9 of 15 heavy metal (Sb, As, Ag, Be, Cd, Mo, Se, Tl, V) concentrations were all below their reporting limits for drinking water, and all other TAL metals (including common soil elements) were substantially below representative AMD conditions.

Journal of Hazardous Toxic and Radioactive WasteVol. 29(3)
Jacobs (United States) (US)
Life below water
Openalex Percentile: Top 91%
Urban Stormwater Management Solutions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.