Bubbler System Design for Regulating Media Oxygen Levels in an Open Testing Environment

Many biological processes are affected by hypoxia. For example, hypoxia has been suggested to be a driver of tendon degeneration especially in conjunction with mechanical stimulation. To better study the effects of both factors on tendon degeneration, tendon explant studies can be useful. However, such explant models are complicated by the need of an incubator to control the oxygen levels, limiting the types of experiments that can be done. In this paper, we describe the design of a bubbler system to alter oxygen levels for experiments conducted in an open environment. The basin volume, basin surface area-to-volume ratio, total system volume, and pump flow rate were optimized to obtain the lowest possible oxygen level. Oxygen levels were most sensitive to the total system volume and pump flow rates with higher values for both parameters leading to lower oxygen readings. This bubbler system was able to reach and maintain hypoxic levels sufficient to conduct future tendon explant experiments to understand the mechanism driving tendinopathy.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanical Engineering
Published
2025-05-09
DOI
https://doi.org/10.1115/1.4068635
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Bubbler System Design for Regulating Media Oxygen Levels in an Open Testing Environment

Spencer E. Szczesny, Margaret Capalbo
Journal of Biomechanical Engineering
Shoulder Injury and Treatment
article

Bubbler System Design for Regulating Media Oxygen Levels in an Open Testing Environment

Spencer E. Szczesny, Margaret Capalbo
article en

Abstract

Many biological processes are affected by hypoxia. For example, hypoxia has been suggested to be a driver of tendon degeneration especially in conjunction with mechanical stimulation. To better study the effects of both factors on tendon degeneration, tendon explant studies can be useful. However, such explant models are complicated by the need of an incubator to control the oxygen levels, limiting the types of experiments that can be done. In this paper, we describe the design of a bubbler system to alter oxygen levels for experiments conducted in an open environment. The basin volume, basin surface area-to-volume ratio, total system volume, and pump flow rate were optimized to obtain the lowest possible oxygen level. Oxygen levels were most sensitive to the total system volume and pump flow rates with higher values for both parameters leading to lower oxygen readings. This bubbler system was able to reach and maintain hypoxic levels sufficient to conduct future tendon explant experiments to understand the mechanism driving tendinopathy.

Journal of Biomechanical EngineeringVol. 147(8)
Pennsylvania State University (US)
Life in Land
Openalex Percentile: Top 83%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.