Noninvasive blood glucose monitoring using a dual band microwave sensor with machine learning

The potential for continuous non-invasive blood glucose monitoring has attracted a lot of interest in the field of medical diagnostics. This paper provides a new shape of a dual-band bandpass filter (DBBPF) acting as a microwave transmission line sensor for continuous non-invasive blood glucose monitoring operating at 2.45 and 5.2 GHz. The proposed system uses the interaction between biological tissues and microwave signals to correctly assess blood glucose levels. The proposed dual-band bandpass filter (DBBPF), comprises three split ring resonator (SRR) cells with different dimensions. It is designed to operate as a sensor with improved sensitivity, compact dimensions, and a high-quality factor. It also ensures a reasonable bandwidth for lower and higher bands of 8.6 and 2%, respectively in the industrial, scientific, medical band, and the wireless local area network (ISM and WLAN) Bands. A dual-band filter enhances measurement sensitivity and specificity by targeting specific frequency ranges where glucose exhibits distinctive dielectric responses, thereby providing redundant data points for accurate glucose level determination. Glucose concentrations can be evaluated by measuring the changes in the dielectric properties of blood by sending microwave waves through the body and assessing the collected S-parameter signals. The measurement parameters encompass the reflection, phase, magnitude, as well as transmission parameters. This yields multiple evaluations of the glucose-induced alterations. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. Machine learning models are employed to analyze the sensor data, improving the accuracy of diabetes detection. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. A Cole-Cole model, implemented using MATLAB, is utilized for the phantom finger model. The main results reveal the success of the proposed transmission-based microwave glucose sensing, with a remarkable sensitivity of 1 ~ 1.5 dB for glucose level change up to 200 mg/dL.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-09
DOI
https://doi.org/10.1038/s41598-025-94367-6
Citations
18
Primary Topic
Wireless Body Area Networks
Type
article
Field-Weighted Citation Impact
12.13

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Noninvasive blood glucose monitoring using a dual band microwave sensor with machine learning

Angie R. Eldamak, Dalia N. Elsheakh, Mohamed Hesham Farouk, Anwer S. Abd El-Hameed
18 citations
Scientific Reports
Wireless Body Area Networks
12.13
article

Noninvasive blood glucose monitoring using a dual band microwave sensor with machine learning

Angie R. Eldamak, Dalia N. Elsheakh, Mohamed Hesham Farouk, Anwer S. Abd El-Hameed
article en
18 citations

Abstract

The potential for continuous non-invasive blood glucose monitoring has attracted a lot of interest in the field of medical diagnostics. This paper provides a new shape of a dual-band bandpass filter (DBBPF) acting as a microwave transmission line sensor for continuous non-invasive blood glucose monitoring operating at 2.45 and 5.2 GHz. The proposed system uses the interaction between biological tissues and microwave signals to correctly assess blood glucose levels. The proposed dual-band bandpass filter (DBBPF), comprises three split ring resonator (SRR) cells with different dimensions. It is designed to operate as a sensor with improved sensitivity, compact dimensions, and a high-quality factor. It also ensures a reasonable bandwidth for lower and higher bands of 8.6 and 2%, respectively in the industrial, scientific, medical band, and the wireless local area network (ISM and WLAN) Bands. A dual-band filter enhances measurement sensitivity and specificity by targeting specific frequency ranges where glucose exhibits distinctive dielectric responses, thereby providing redundant data points for accurate glucose level determination. Glucose concentrations can be evaluated by measuring the changes in the dielectric properties of blood by sending microwave waves through the body and assessing the collected S-parameter signals. The measurement parameters encompass the reflection, phase, magnitude, as well as transmission parameters. This yields multiple evaluations of the glucose-induced alterations. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. Machine learning models are employed to analyze the sensor data, improving the accuracy of diabetes detection. Simulations are validated through laboratory measurements incorporating a phantom finger model for capturing realistic outcomes. A Cole-Cole model, implemented using MATLAB, is utilized for the phantom finger model. The main results reveal the success of the proposed transmission-based microwave glucose sensing, with a remarkable sensitivity of 1 ~ 1.5 dB for glucose level change up to 200 mg/dL.

Scientific ReportsVol. 15(1)
Ain Shams University (EG), Badr University in Cairo (EG), Electronics Research Institute (EG)
Science and Technology Development Fund
Openalex Percentile: Top 1%
Wireless Body Area Networks
12.13
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.