2D Polynomial Regression Modeling for Predictive Analysis of Glucose Concentration in NP-Model Fractal Microwave Sensor Using Frequency and Transmission Coefficient Disparities

The article introduces a two-dimensional polynomial regression model for the predictive analysis of glucose concentration in a fractal microwave sensor NP model, utilizing frequency and transmission coefficient differences to examine their correlation with glucose concentration levels. The sensor employed in this investigation is fabricated on an economical FR-4 substrate to minimize costs. The sensor structure is developed with the fractal structure reduction method established by the NP model to operate at a frequency of roughly 2.97 GHz. The CST Studio software is utilized to analyze the findings from the simulation of the suggested sensor structure. Furthermore, the proposed sensor is integrated into a test apparatus comprising a sensor platform and a liquid tube constructed from PPA material. The liquid under examination is a glucose and water mixture at varying concentrations. It was analyzed using a VNA instrument to evaluate its frequency response and the magnitude of the alteration in the transmission coefficient. The values are utilized to create a two-dimensional polynomial regression model. The experiments demonstrated that the proposed sensor model possesses an Adjusted R² value of 0.99499 and an average error of approximately 3.57% for glucose concentration analysis throughout the range of 5% to 30%, with sensitivities of 0.00879 dB/% for insertion loss and 0.092 MHz/% for frequency variation, facilitating accurate glucose concentration prediction analysis.

Authors

Institutions

Publication Details

Published
2025-03-05
DOI
https://doi.org/10.1109/ieecon64081.2025.10987708
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

2D Polynomial Regression Modeling for Predictive Analysis of Glucose Concentration in NP-Model Fractal Microwave Sensor Using Frequency and Transmission Coefficient Disparities

Norakamon Wongsin, Wilaiporn Lee, Nutyada Nantapanich, Pisit Mahatthanajatuphat
Spectroscopy and Chemometric Analyses
article

2D Polynomial Regression Modeling for Predictive Analysis of Glucose Concentration in NP-Model Fractal Microwave Sensor Using Frequency and Transmission Coefficient Disparities

Norakamon Wongsin, Wilaiporn Lee, Nutyada Nantapanich, Pisit Mahatthanajatuphat
article en

Abstract

The article introduces a two-dimensional polynomial regression model for the predictive analysis of glucose concentration in a fractal microwave sensor NP model, utilizing frequency and transmission coefficient differences to examine their correlation with glucose concentration levels. The sensor employed in this investigation is fabricated on an economical FR-4 substrate to minimize costs. The sensor structure is developed with the fractal structure reduction method established by the NP model to operate at a frequency of roughly 2.97 GHz. The CST Studio software is utilized to analyze the findings from the simulation of the suggested sensor structure. Furthermore, the proposed sensor is integrated into a test apparatus comprising a sensor platform and a liquid tube constructed from PPA material. The liquid under examination is a glucose and water mixture at varying concentrations. It was analyzed using a VNA instrument to evaluate its frequency response and the magnitude of the alteration in the transmission coefficient. The values are utilized to create a two-dimensional polynomial regression model. The experiments demonstrated that the proposed sensor model possesses an Adjusted R² value of 0.99499 and an average error of approximately 3.57% for glucose concentration analysis throughout the range of 5% to 30%, with sensitivities of 0.00879 dB/% for insertion loss and 0.092 MHz/% for frequency variation, facilitating accurate glucose concentration prediction analysis.

Rajamangala University of Technology (TH), King Mongkut's University of Technology North Bangkok (TH)
King Mongkut's University of Technology North Bangkok, Innovation Fund
Zero hunger
Openalex Percentile: Top 89%
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.