Compact 8-Channel Phased Array Stepped Impedance RF Coil for 9.4 Tesla Spinal Cord MRI

This article proposes a novel 8-channel Stepped Impedance Structure (SIS) RF coil for spinal cord imaging applications at 9.4 Tesla. The presented RF coil comprises eight stepped impedance structured elements arranged in a phased array configuration, each channel spaced 6mm apart on a 17 x 50 cm substrate. The SIS RF coil incorporates three distinct impedance levels and a capacitor-capacitor (CC) matching network to achieve resonance at 400 MHz. To evaluate the effectiveness of the designed RF coil, a comparative analysis of various spacing configurations specifically with 5mm and 10mm gaps between the channels of RF coil. The phased array RF coil functionality is assessed through S-parameter analysis, demonstrating a return loss of 36 dB at the operating frequency. The study confirms that the proposed RF coil achieves the desired frequency and performance characteristic making it an effective candidate for integration into the spinal cord MRI system.

Authors

Publication Details

Published
2025-03-06
DOI
https://doi.org/10.1109/iatmsi64286.2025.10985431
Primary Topic
Advanced MRI Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Compact 8-Channel Phased Array Stepped Impedance RF Coil for 9.4 Tesla Spinal Cord MRI

N. Saranya, T. Deepa, R. Janani, P. Raja et al.
Advanced MRI Techniques and Applications
article

Compact 8-Channel Phased Array Stepped Impedance RF Coil for 9.4 Tesla Spinal Cord MRI

N. Saranya, T. Deepa, R. Janani, P. Raja, K Raghavardhini, B Vighneshwara
article en

Abstract

This article proposes a novel 8-channel Stepped Impedance Structure (SIS) RF coil for spinal cord imaging applications at 9.4 Tesla. The presented RF coil comprises eight stepped impedance structured elements arranged in a phased array configuration, each channel spaced 6mm apart on a 17 x 50 cm substrate. The SIS RF coil incorporates three distinct impedance levels and a capacitor-capacitor (CC) matching network to achieve resonance at 400 MHz. To evaluate the effectiveness of the designed RF coil, a comparative analysis of various spacing configurations specifically with 5mm and 10mm gaps between the channels of RF coil. The phased array RF coil functionality is assessed through S-parameter analysis, demonstrating a return loss of 36 dB at the operating frequency. The study confirms that the proposed RF coil achieves the desired frequency and performance characteristic making it an effective candidate for integration into the spinal cord MRI system.

Affordable and clean energy
Openalex Percentile: Top 85%
Advanced MRI Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.