Machine Learning in Predicting the Impact of Filter Parameters on the Accuracy of Biosignal Measurement

In this scientific article under consideration, a machine learning model has been developed that allows predicting the impact of filter parameters on the accuracy of measuring a biosignal - an ECG (electrocardiography) signal. For the first time, quantitative results have shown the degree of influence and the error introduced into the measured biosignal and described through dependence. The results of assessing the obtained relationship of indicators demonstrate an inverse correlation relationship that characterizes a decrease in the accuracy of measurement at the output of a high-order digital filtering system. The machine learning model is based on the linear regression method the dependence of which is approximated by the method based on least squares and visualized using a scattergram. The adequacy of the developed machine learning model was confirmed by calculating the coefficient of determination and checking its statistical significance. The developed model can be used to create new or improve existing biomedical data processing systems to increase the reliability of the results.

Authors

Institutions

Publication Details

Published
2025-03-26
DOI
https://doi.org/10.1109/dspa64310.2025.10977869
Citations
1
Primary Topic
Engineering Technology and Methodologies
Type
article
Field-Weighted Citation Impact
1.24
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Machine Learning in Predicting the Impact of Filter Parameters on the Accuracy of Biosignal Measurement

Yeldos A. Altay, Abu-Alim Ayazbay, Raissa Uskenbayeva, Alexey V. Fedorov
1 citations
Engineering Technology and Methodologies
1.24
article

Machine Learning in Predicting the Impact of Filter Parameters on the Accuracy of Biosignal Measurement

Yeldos A. Altay, Abu-Alim Ayazbay, Raissa Uskenbayeva, Alexey V. Fedorov
article en
1 citations

Abstract

In this scientific article under consideration, a machine learning model has been developed that allows predicting the impact of filter parameters on the accuracy of measuring a biosignal - an ECG (electrocardiography) signal. For the first time, quantitative results have shown the degree of influence and the error introduced into the measured biosignal and described through dependence. The results of assessing the obtained relationship of indicators demonstrate an inverse correlation relationship that characterizes a decrease in the accuracy of measurement at the output of a high-order digital filtering system. The machine learning model is based on the linear regression method the dependence of which is approximated by the method based on least squares and visualized using a scattergram. The adequacy of the developed machine learning model was confirmed by calculating the coefficient of determination and checking its statistical significance. The developed model can be used to create new or improve existing biomedical data processing systems to increase the reliability of the results.

ITMO University (RU), Satbayev University (KZ), Almaty University of Power Engineering and Telecommunications (KZ)
Affordable and clean energy
Openalex Percentile: Top 20%
Engineering Technology and Methodologies
1.24
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.