Multi-Feature Transformer-Based Learning for Remote and Accurate Vital Sign Estimation Using mmWave FMCW Radar

Non-contact measurement of vital signs is an important issue in modern healthcare, aimed at enhancing patient comfort and convenience. Achieving sufficient measurement distance and adaptability to patient movement is essential for effectiveness. Current research covers measurement ranges between 1 and 3.5 meters. This study introduces a novel multifeature transformer-based super-resolution model. By inputting and encoding low-resolution sequences of distance, phase, and phase variation rates, the model upsamples these sequences, generating additional sample points and transforming the lowresolution data into high-resolution sequences. This process improves the quality and range of FMCW radar measurements by increasing the sample points, enabling the model to extract vital sign information from low-resolution sequences and produce accurate results. From the generated high-resolution sequences, vital signs such as heart rate and respiration are then extracted. Experimental results show that, at a distance of 5 meters, the system achieves 87.3 accuracy for heart rate and 89.1 accuracy for respiration in a walking scenario, outperforming existing solutions by 8.6 % and 6.5 %, respectively.

Authors

Institutions

Publication Details

Published
2025-03-24
DOI
https://doi.org/10.1109/wcnc61545.2025.10978740
Citations
1
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Multi-Feature Transformer-Based Learning for Remote and Accurate Vital Sign Estimation Using mmWave FMCW Radar

Jing Lyu, Chih‐Shun Hsu, Yuh‐Shyan Chen
1 citations
Non-Invasive Vital Sign Monitoring
0.67
article

Multi-Feature Transformer-Based Learning for Remote and Accurate Vital Sign Estimation Using mmWave FMCW Radar

Jing Lyu, Chih‐Shun Hsu, Yuh‐Shyan Chen
article en
1 citations

Abstract

Non-contact measurement of vital signs is an important issue in modern healthcare, aimed at enhancing patient comfort and convenience. Achieving sufficient measurement distance and adaptability to patient movement is essential for effectiveness. Current research covers measurement ranges between 1 and 3.5 meters. This study introduces a novel multifeature transformer-based super-resolution model. By inputting and encoding low-resolution sequences of distance, phase, and phase variation rates, the model upsamples these sequences, generating additional sample points and transforming the lowresolution data into high-resolution sequences. This process improves the quality and range of FMCW radar measurements by increasing the sample points, enabling the model to extract vital sign information from low-resolution sequences and produce accurate results. From the generated high-resolution sequences, vital signs such as heart rate and respiration are then extracted. Experimental results show that, at a distance of 5 meters, the system achieves 87.3 accuracy for heart rate and 89.1 accuracy for respiration in a walking scenario, outperforming existing solutions by 8.6 % and 6.5 %, respectively.

Shih Hsin University (TW), National Taipei University (TW)
Affordable and clean energy
Openalex Percentile: Top 32%
Non-Invasive Vital Sign Monitoring
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.