Effect of Source Polarization on Computed Tomography using Low Frequency Electromagnetic Energy

We have shown in recent work that computed tomography (CT) using low-frequency electromagnetic energy provides a resolution significantly below the diffraction limit, as long as the object under examination is electrically very small. This encouraging finding was based on the “ray-like” behavior of electromagnetic energy when traversing electrically small objects. However, and distinct from the X-ray based CT modality, low-frequency energy provides an additional feature which is not available in X rays, namely polarization. This work explores numerically the effect of source polarization on the CT using low frequency electromagnetic energy. These findings may have strong implications in providing higher contrast for specific body anomalies and may provide contrast between benign and malignant tumors.

Authors

Institutions

Publication Details

Published
2024-10-09
DOI
https://doi.org/10.1109/cama62287.2024.10986225
Primary Topic
Atomic and Subatomic Physics Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Source Polarization on Computed Tomography using Low Frequency Electromagnetic Energy

Omar M. Ramahi, Hamid Akbari–Chelaresi, Mauricio Hernandez, Ghazaleh Tashtarian
1 links
Atomic and Subatomic Physics Research
article

Effect of Source Polarization on Computed Tomography using Low Frequency Electromagnetic Energy

Omar M. Ramahi, Hamid Akbari–Chelaresi, Mauricio Hernandez, Ghazaleh Tashtarian
article en

Abstract

We have shown in recent work that computed tomography (CT) using low-frequency electromagnetic energy provides a resolution significantly below the diffraction limit, as long as the object under examination is electrically very small. This encouraging finding was based on the “ray-like” behavior of electromagnetic energy when traversing electrically small objects. However, and distinct from the X-ray based CT modality, low-frequency energy provides an additional feature which is not available in X rays, namely polarization. This work explores numerically the effect of source polarization on the CT using low frequency electromagnetic energy. These findings may have strong implications in providing higher contrast for specific body anomalies and may provide contrast between benign and malignant tumors.

University of Waterloo (CA)
Affordable and clean energy
Openalex Percentile: Top 76%
Atomic and Subatomic Physics Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.