Alternative Protection of Electrical Installations

The paper presents the principle of operation of the developed maximum current protection, the purpose of which is to protect high-voltage electrical installations from short circuits. The presented protection is performed without using current relays and current transformers (CT) with ferromagnetic cores (including those built into the circuit breaker) widely used in the electric power industry, which have a large weight and dimensional parameters, as well as high cost in comparison with magnetosensitive elements such as reed switches. The proposed protection is made with the use of reed switches. Current protections of electrical installations with the use of reed switches can be used at the moment only as a duplicate to traditional protections, as there is no their wide introduction into production and experience of operation of such protections, i.e. statistical data on these protections are required. At the same time it should be said that such protections are not inferior to traditional protections in terms of speed. The presented protection characterizes an innovative approach in the implementation of relay protection and has the effect of resource-saving materials. The proposed maximum current protection is performed in the form of a device, with its installation inside the circuit breaker located in the cell of a closed switchgear (switchgear) with a voltage equal to 35 kV.

Authors

Institutions

Publication Details

Published
2025-03-24
DOI
https://doi.org/10.1109/smartindustrycon65166.2025.10986203
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Alternative Protection of Electrical Installations

Dauren D. Issabekov
Electrical Fault Detection and Protection
article

Alternative Protection of Electrical Installations

Dauren D. Issabekov
article en

Abstract

The paper presents the principle of operation of the developed maximum current protection, the purpose of which is to protect high-voltage electrical installations from short circuits. The presented protection is performed without using current relays and current transformers (CT) with ferromagnetic cores (including those built into the circuit breaker) widely used in the electric power industry, which have a large weight and dimensional parameters, as well as high cost in comparison with magnetosensitive elements such as reed switches. The proposed protection is made with the use of reed switches. Current protections of electrical installations with the use of reed switches can be used at the moment only as a duplicate to traditional protections, as there is no their wide introduction into production and experience of operation of such protections, i.e. statistical data on these protections are required. At the same time it should be said that such protections are not inferior to traditional protections in terms of speed. The presented protection characterizes an innovative approach in the implementation of relay protection and has the effect of resource-saving materials. The proposed maximum current protection is performed in the form of a device, with its installation inside the circuit breaker located in the cell of a closed switchgear (switchgear) with a voltage equal to 35 kV.

Toraighyrov University (KZ)
Openalex Percentile: Top 92%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Alternative Protection of Electrical Installations — Dauren D. Issabekov · (2025) | TGRS Research Map | TGRS