The Influence of Shielding Enclosure on the Characteristics of Protection Devices Operating in Differential and Common Modes

In this work, we used quasi-static simulation to evaluate the influence of shielding enclosure on the attenuation coefficient and per-unit-length delays of devices protecting against ultra-wideband pulses. The protection devices were 6-and 8-conductor structures, each consisting of two transmission lines with inhomogeneous dielectric filling, combined into one structure. The simulation showed that increasing the distance between the shield walls and the 6-conductor structure resulted in the same attenuation coefficients as without the shield. Therefore, the shield should be kept as far away as possible to preserve the characteristics. In the 8-conductor structure, increasing the distance to the shield walls had a non-significant influence on the attenuation coefficient in the common and differential modes. This probably happened because the active conductors were placed in the central part (inside) of the structure cross-section. The per-unit-length mode delays in both structures were not influenced by changing distances to the walls.

Authors

Institutions

Publication Details

Published
2025-03-24
DOI
https://doi.org/10.1109/smartindustrycon65166.2025.10986028
Citations
1
Primary Topic
Transportation Systems and Safety
Type
article
Field-Weighted Citation Impact
3.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The Influence of Shielding Enclosure on the Characteristics of Protection Devices Operating in Differential and Common Modes

Alexandr M. Lakoza, Evgeniya B. Chernikova, Valerii P. Kosteletskii
1 citations
Transportation Systems and Safety
3.54
article

The Influence of Shielding Enclosure on the Characteristics of Protection Devices Operating in Differential and Common Modes

Alexandr M. Lakoza, Evgeniya B. Chernikova, Valerii P. Kosteletskii
article en
1 citations

Abstract

In this work, we used quasi-static simulation to evaluate the influence of shielding enclosure on the attenuation coefficient and per-unit-length delays of devices protecting against ultra-wideband pulses. The protection devices were 6-and 8-conductor structures, each consisting of two transmission lines with inhomogeneous dielectric filling, combined into one structure. The simulation showed that increasing the distance between the shield walls and the 6-conductor structure resulted in the same attenuation coefficients as without the shield. Therefore, the shield should be kept as far away as possible to preserve the characteristics. In the 8-conductor structure, increasing the distance to the shield walls had a non-significant influence on the attenuation coefficient in the common and differential modes. This probably happened because the active conductors were placed in the central part (inside) of the structure cross-section. The per-unit-length mode delays in both structures were not influenced by changing distances to the walls.

Tomsk State University of Control Systems and Radio-Electronics (RU)
Openalex Percentile: Top 10%
Transportation Systems and Safety
3.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.