Observer-Based Finite-Time Fuzzy Load Frequency Control for Multiarea Nonlinear Power Systems Under Input Delays and Cyber Attacks

This paper presents an observer-based finite-time fuzzy load frequency control (LFC) strategy for multiarea nonlinear power systems with uncertain parameters, considering the impact of cyber attacks and input delays. To tackle the nonlinearities and uncertainties, an LFC model incorporating multiple input delays is developed within the interval type-2 (IT2) Takagi-Sugeno (T-S) fuzzy framework. In response to unmeasurable states and unknown false data injection attacks (FDIAs), state and attack observers are designed to estimate these unknowns, thereby enabling effective compensation for FDIAs during the controller design. Furthermore, an observer-based reduction method is employed to transform the multiple input-delay system into a delay-free one, which reduces conservatism. Sufficient conditions are derived such that the closed-loop system is finite-time stable with H∞ performance. Finally, simulations demonstrate the effectiveness of the proposed method.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Smart Grid
Published
2025-05-09
DOI
https://doi.org/10.1109/tsg.2025.3567970
Citations
3
Primary Topic
Frequency Control in Power Systems
Type
article
Field-Weighted Citation Impact
2.19

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Observer-Based Finite-Time Fuzzy Load Frequency Control for Multiarea Nonlinear Power Systems Under Input Delays and Cyber Attacks

Zhiyong Wang, Juan Zhang, Huaguang Zhang, Jing Dai
3 citations
IEEE Transactions on Smart Grid
Frequency Control in Power Systems
2.19
article

Observer-Based Finite-Time Fuzzy Load Frequency Control for Multiarea Nonlinear Power Systems Under Input Delays and Cyber Attacks

Zhiyong Wang, Juan Zhang, Huaguang Zhang, Jing Dai
article en
3 citations

Abstract

This paper presents an observer-based finite-time fuzzy load frequency control (LFC) strategy for multiarea nonlinear power systems with uncertain parameters, considering the impact of cyber attacks and input delays. To tackle the nonlinearities and uncertainties, an LFC model incorporating multiple input delays is developed within the interval type-2 (IT2) Takagi-Sugeno (T-S) fuzzy framework. In response to unmeasurable states and unknown false data injection attacks (FDIAs), state and attack observers are designed to estimate these unknowns, thereby enabling effective compensation for FDIAs during the controller design. Furthermore, an observer-based reduction method is employed to transform the multiple input-delay system into a delay-free one, which reduces conservatism. Sufficient conditions are derived such that the closed-loop system is finite-time stable with H∞ performance. Finally, simulations demonstrate the effectiveness of the proposed method.

IEEE Transactions on Smart GridVol. 16(4)
Tsinghua Sichuan Energy Internet Research Institute (CN), Northeastern University (CN), Tsinghua University (CN)
National Natural Science Foundation of China, Liaoning Revitalization Talents Program, National Key Research and Development Program of China
Affordable and clean energy
Openalex Percentile: Top 12%
Frequency Control in Power Systems
2.19
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.