Stator Current Calculation and Validation for DFIGs With Multiple Control Strategies Under Weak Grid Faults

This paper investigates the fault current characteristics of doubly-fed induction generators (DFIGs) in weak grid scenarios, addressing the limitations of existing methods that assume a predefined voltage dip and neglect the influence of DFIGs on post-fault voltage. A transient fault voltage model is proposed to accurately capture the interaction between DFIGs and weak grid impedance, which significantly affects fault current calculation. The model introduces an additional pole to account for fault voltage transients, addressing computational errors in low grid strength conditions. Furthermore, a fault current expression for DFIGs under severe faults, particularly after crowbar activation, is derived, revealing the impact of external grid impedance on transient fault currents. Case studies with expanded fault scenarios and hardware-in-loop experiments demonstrate the superiority of the proposed method over existing approaches in weak grid applications.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Industry Applications
Published
2025-05-09
DOI
https://doi.org/10.1109/tia.2025.3568799
Primary Topic
Electric Motor Design and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Stator Current Calculation and Validation for DFIGs With Multiple Control Strategies Under Weak Grid Faults

Jianzhe Liu, Sheng Liu, Xubin Liu, Juan Wei et al.
IEEE Transactions on Industry Applications
Electric Motor Design and Analysis
article

Stator Current Calculation and Validation for DFIGs With Multiple Control Strategies Under Weak Grid Faults

Jianzhe Liu, Sheng Liu, Xubin Liu, Juan Wei, Canbing Li, Dawei Chen, Feilong Fan
article en

Abstract

This paper investigates the fault current characteristics of doubly-fed induction generators (DFIGs) in weak grid scenarios, addressing the limitations of existing methods that assume a predefined voltage dip and neglect the influence of DFIGs on post-fault voltage. A transient fault voltage model is proposed to accurately capture the interaction between DFIGs and weak grid impedance, which significantly affects fault current calculation. The model introduces an additional pole to account for fault voltage transients, addressing computational errors in low grid strength conditions. Furthermore, a fault current expression for DFIGs under severe faults, particularly after crowbar activation, is derived, revealing the impact of external grid impedance on transient fault currents. Case studies with expanded fault scenarios and hardware-in-loop experiments demonstrate the superiority of the proposed method over existing approaches in weak grid applications.

IEEE Transactions on Industry ApplicationsVol. 61(5)
Central South University (CN), Hunan University (CN), Shanghai Jiao Tong University (CN)
Affordable and clean energy
Openalex Percentile: Top 92%
Electric Motor Design and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Stator Current Calculation and Validation for DFIGs With Multiple Control Strategies Under Weak Grid Faults — Jianzhe Liu, Sheng Liu, et al. · IEEE Transactions on Industry Applications (2025) | TGRS Research Map | TGRS