A Locating Harmonic Radar-Based Sensor for Vital-Sign Health Monitoring With Ultra-Low Power Harmonic Conversion Loss Compensation

As living standards improve, the demand for health monitoring continues to rise. The daily continuous monitoring over the long term is still facing challenges due to limited technology advances with well body comfort. This article proposes a wireless nonintrusive sensing system based on a harmonic radar sensor (HRS) system. The HRS transponder is used as a sensing node placed on the surface of the target’s thoracic cavity. Through an I/Q-modulated harmonic reader architecture, information from the HRS is acquired. The amplitude and phase information demodulated by the HRS transceiver are used for vital sign detection and target localization, respectively. In this study, we successfully conduct the wireless harmonic sensing experiment for vital sign sensing with the capability for transponder localization. The measured vital sign signals show a good consistency with commercial electrocardiograph (ECG) reference signals in terms of heartbeat intervals. Furthermore, the system achieves precise localization of the transponder, with a positioning error of less than 6 cm with the probability of 95%. Empirical evidence demonstrates that the proposed HRS-based system exhibits superior and more stable detection performance compared with conventional passive harmonic methods. Furthermore, our proposed active HRS extends the maximum detection range of passive harmonic tags from 2 to 3 m. This improvement arises from the system’s active architecture, which integrates a reflective amplifier to enhance signal strength by 12 dB at 1.8 GHz. The experimental results also indicate that the wireless sensing architecture based on HRS in this work is a potential candidate for future healthcare systems.

Authors

Institutions

Publication Details

Journal
IEEE Transactions on Microwave Theory and Techniques
Published
2025-05-09
DOI
https://doi.org/10.1109/tmtt.2025.3564475
Citations
3
Primary Topic
Non-Invasive Vital Sign Monitoring
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Locating Harmonic Radar-Based Sensor for Vital-Sign Health Monitoring With Ultra-Low Power Harmonic Conversion Loss Compensation

Xianmin Zhang, Xiaonan Hui, Chenming Li, Ian Pratt et al.
3 citations
IEEE Transactions on Microwave Theory and Techniques
Non-Invasive Vital Sign Monitoring
2.02
article

A Locating Harmonic Radar-Based Sensor for Vital-Sign Health Monitoring With Ultra-Low Power Harmonic Conversion Loss Compensation

Xianmin Zhang, Xiaonan Hui, Chenming Li, Ian Pratt, Shilie Zheng, Yuqi Chen, Yulin Zhou, Xiaoying Zheng, Bincai Wu
article en
3 citations

Abstract

As living standards improve, the demand for health monitoring continues to rise. The daily continuous monitoring over the long term is still facing challenges due to limited technology advances with well body comfort. This article proposes a wireless nonintrusive sensing system based on a harmonic radar sensor (HRS) system. The HRS transponder is used as a sensing node placed on the surface of the target’s thoracic cavity. Through an I/Q-modulated harmonic reader architecture, information from the HRS is acquired. The amplitude and phase information demodulated by the HRS transceiver are used for vital sign detection and target localization, respectively. In this study, we successfully conduct the wireless harmonic sensing experiment for vital sign sensing with the capability for transponder localization. The measured vital sign signals show a good consistency with commercial electrocardiograph (ECG) reference signals in terms of heartbeat intervals. Furthermore, the system achieves precise localization of the transponder, with a positioning error of less than 6 cm with the probability of 95%. Empirical evidence demonstrates that the proposed HRS-based system exhibits superior and more stable detection performance compared with conventional passive harmonic methods. Furthermore, our proposed active HRS extends the maximum detection range of passive harmonic tags from 2 to 3 m. This improvement arises from the system’s active architecture, which integrates a reflective amplifier to enhance signal strength by 12 dB at 1.8 GHz. The experimental results also indicate that the wireless sensing architecture based on HRS in this work is a potential candidate for future healthcare systems.

IEEE Transactions on Microwave Theory and TechniquesVol. 73(8)
University of Nottingham Ningbo China (CN), Zhejiang University (CN)
National Natural Science Foundation of China, Ministry of Science and Technology of the People's Republic of China, Kyoto University Education and Research Foundation
Affordable and clean energy
Openalex Percentile: Top 14%
Non-Invasive Vital Sign Monitoring
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.