A Locating Harmonic Radar-Based Sensor for Vital-Sign Health Monitoring With Ultra-Low Power Harmonic Conversion Loss Compensation
As living standards improve, the demand for health monitoring continues to rise. The daily continuous monitoring over the long term is still facing challenges due to limited technology advances with well body comfort. This article proposes a wireless nonintrusive sensing system based on a harmonic radar sensor (HRS) system. The HRS transponder is used as a sensing node placed on the surface of the target’s thoracic cavity. Through an I/Q-modulated harmonic reader architecture, information from the HRS is acquired. The amplitude and phase information demodulated by the HRS transceiver are used for vital sign detection and target localization, respectively. In this study, we successfully conduct the wireless harmonic sensing experiment for vital sign sensing with the capability for transponder localization. The measured vital sign signals show a good consistency with commercial electrocardiograph (ECG) reference signals in terms of heartbeat intervals. Furthermore, the system achieves precise localization of the transponder, with a positioning error of less than 6 cm with the probability of 95%. Empirical evidence demonstrates that the proposed HRS-based system exhibits superior and more stable detection performance compared with conventional passive harmonic methods. Furthermore, our proposed active HRS extends the maximum detection range of passive harmonic tags from 2 to 3 m. This improvement arises from the system’s active architecture, which integrates a reflective amplifier to enhance signal strength by 12 dB at 1.8 GHz. The experimental results also indicate that the wireless sensing architecture based on HRS in this work is a potential candidate for future healthcare systems.
Authors
- Xianmin Zhang (ORCID: https://orcid.org/0000-0002-0660-0213)
- Xiaonan Hui (ORCID: https://orcid.org/0000-0002-3378-5225)
- Chenming Li (ORCID: https://orcid.org/0009-0008-1211-6496)
- Ian Pratt (ORCID: https://orcid.org/0009-0009-2825-1550)
- Shilie Zheng (ORCID: https://orcid.org/0000-0001-7149-7497)
- Yuqi Chen (ORCID: https://orcid.org/0000-0003-1900-651X)
- Yulin Zhou (ORCID: https://orcid.org/0000-0002-9374-8186)
- Xiaoying Zheng
- Bincai Wu
Institutions
- University of Nottingham Ningbo China (CN)
- Zhejiang University (CN)
Publication Details
- Journal
- IEEE Transactions on Microwave Theory and Techniques
- Published
- 2025-05-09
- DOI
- https://doi.org/10.1109/tmtt.2025.3564475
- Citations
- 3
- Primary Topic
- Non-Invasive Vital Sign Monitoring
- Type
- article
- Field-Weighted Citation Impact
- 2.02
Funders
- National Natural Science Foundation of China
- Ministry of Science and Technology of the People's Republic of China
- Kyoto University Education and Research Foundation