Dual Light Sources Interferometry Measures the Refractive Index to Estimate Ethanol Concentration

High-precision, rapid, non-contact measurement of solution concentrations is crucial for accurate formulation. In this paper, we introduce an ethanol concentration interferometer based on low-coherence interferometry (LCI) technology, utilizing a dual-light source and a microcavity method. The system features a modified Michelson interferometer structure, conducting measurements with both 1310 nm broadband light and 1550 nm narrowband light. It employs a long optical path optical delay line to achieve high linearity in axial scanning (R2=0.9979). Ultimately, this method achieves a measurement accuracy of 1e-3 for the group refractive index of alcohol solutions ranging from 30% to 75%.

Authors

Institutions

Publication Details

Journal
IEEE Photonics Technology Letters
Published
2025-05-09
DOI
https://doi.org/10.1109/lpt.2025.3568391
Primary Topic
Spectroscopy and Chemometric Analyses
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dual Light Sources Interferometry Measures the Refractive Index to Estimate Ethanol Concentration

Wenzheng Ding, Haoran Huang, Xiang Liu, Mingyi Wang et al.
IEEE Photonics Technology Letters
Spectroscopy and Chemometric Analyses
article

Dual Light Sources Interferometry Measures the Refractive Index to Estimate Ethanol Concentration

Wenzheng Ding, Haoran Huang, Xiang Liu, Mingyi Wang, Yaguang Zeng, Feng Guan
article en

Abstract

High-precision, rapid, non-contact measurement of solution concentrations is crucial for accurate formulation. In this paper, we introduce an ethanol concentration interferometer based on low-coherence interferometry (LCI) technology, utilizing a dual-light source and a microcavity method. The system features a modified Michelson interferometer structure, conducting measurements with both 1310 nm broadband light and 1550 nm narrowband light. It employs a long optical path optical delay line to achieve high linearity in axial scanning (R2=0.9979). Ultimately, this method achieves a measurement accuracy of 1e-3 for the group refractive index of alcohol solutions ranging from 30% to 75%.

IEEE Photonics Technology LettersVol. 37(15)
Foshan University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 89%
Spectroscopy and Chemometric Analyses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.