Impact of Residual Intimal Flap Displacement Post-TEVAR on TBAD Haemodynamics in Compliant, Patient-specific CFD Simulations Informed by MRI

We propose a novel formulation of a moving boundary method to account for the motion of the intimal flap (IF) in a TBAD post-thoracic endovascular aortic repair using patient-specific compliant computational fluid dynamics simulations. The simulations were informed by non-invasive 4D flow MRI sequences. Predicted flow waveforms, aortic wall, and IF displacements were validated against in vivo 4D flow MRI and cine-MRI data. The patient-specific simulation showed that at peak systole, the dynamic interplay between high IF displacement and high transmural pressures promoted true lumen compression and false lumen expansion, whilst luminal patterns were reversed at the deceleration phase. High vorticity and swirling flow patterns were observed throughout the cardiac cycle at the primary entry tear, the descending aorta and proximal to the visceral aortic branches, correlating with high relative residence time, which could indicate an increased localised risk of aortic growth proximal to the IF. A rigid IF simulation revealed significant discrepancies in haemodynamic metrics, highlighting the potential mispredictions when using a rigid wall assumption to assess disease progression. Simulations assuming a more compliant IF highlighted potential increased risks of visceral branches malperfusion and localised aortic wall degeneration. The study underscores the necessity of patient-specific compliant IF simulations for accurate TBAD haemodynamic assessments. These insights can improve disease understanding and inform future treatment strategies.

Authors

Institutions

Publication Details

Journal
Annals of Biomedical Engineering
Published
2025-05-09
DOI
https://doi.org/10.1007/s10439-025-03739-6
Citations
3
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
4.56

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Impact of Residual Intimal Flap Displacement Post-TEVAR on TBAD Haemodynamics in Compliant, Patient-specific CFD Simulations Informed by MRI

Louis Girardin, Vanessa Díaz‐Zuccarini, Hendrik von Tengg‐Kobligk, Stavroula Balabani et al.
3 citations
Annals of Biomedical Engineering
Aortic Disease and Treatment Approaches
4.56
article

Impact of Residual Intimal Flap Displacement Post-TEVAR on TBAD Haemodynamics in Compliant, Patient-specific CFD Simulations Informed by MRI

Louis Girardin, Vanessa Díaz‐Zuccarini, Hendrik von Tengg‐Kobligk, Stavroula Balabani, Niklas Lind
article en
3 citations

Abstract

We propose a novel formulation of a moving boundary method to account for the motion of the intimal flap (IF) in a TBAD post-thoracic endovascular aortic repair using patient-specific compliant computational fluid dynamics simulations. The simulations were informed by non-invasive 4D flow MRI sequences. Predicted flow waveforms, aortic wall, and IF displacements were validated against in vivo 4D flow MRI and cine-MRI data. The patient-specific simulation showed that at peak systole, the dynamic interplay between high IF displacement and high transmural pressures promoted true lumen compression and false lumen expansion, whilst luminal patterns were reversed at the deceleration phase. High vorticity and swirling flow patterns were observed throughout the cardiac cycle at the primary entry tear, the descending aorta and proximal to the visceral aortic branches, correlating with high relative residence time, which could indicate an increased localised risk of aortic growth proximal to the IF. A rigid IF simulation revealed significant discrepancies in haemodynamic metrics, highlighting the potential mispredictions when using a rigid wall assumption to assess disease progression. Simulations assuming a more compliant IF highlighted potential increased risks of visceral branches malperfusion and localised aortic wall degeneration. The study underscores the necessity of patient-specific compliant IF simulations for accurate TBAD haemodynamic assessments. These insights can improve disease understanding and inform future treatment strategies.

Annals of Biomedical EngineeringVol. 53(8)
University Hospital of Bern (CH), Wellcome / EPSRC Centre for Interventional and Surgical Sciences (GB), The London College (GB), University College London (GB)
UK Research and Innovation, British Heart Foundation, University College London, Wellcome / EPSRC Centre for Interventional and Surgical Sciences, Directorate for Biological Sciences, Engineering and Physical Sciences Research Council, Biotechnology and Biological Sciences Research Council
Good health and well-being
Openalex Percentile: Top 6%
Aortic Disease and Treatment Approaches
4.56
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.