At-home validation of a non-contact, radar-based breathing monitor for long-term care of patients with respiratory diseases: A proof-of-concept study

Long-term monitoring of respiratory rate (RR) is an important component in the management of chronic respiratory diseases (CRDs). Specifically, predicting acute exacerbations of chronic obstructive pulmonary disease (AECOPD) is of significant scientific and clinical interest. This study aimed to evaluate the long-term validity of a novel contactless sleep monitor (CSM) in the home environment of CRD patients receiving ventilatory support. Additionally, we assessed patient acceptance, device usability, and RR fluctuations associated with AECOPD to establish a robust foundation for future research.In this prospective proof-of-concept study, nineteen patients requiring non-invasive ventilation (NIV) were provided with the CSM in their home environment for six months and seven patients requiring invasive mechanical ventilation (IMV) for one month. The primary indication for NIV therapy was chronic obstructive pulmonary disease (COPD).The CSM was validated under real-life conditions by comparing its nocturnal RR values with software data from both types of ventilators. Acceptability and usability of the sensor were assessed using a questionnaire. Additionally, COPD exacerbations occurring during the study period were analyzed for potential RR fluctuations preceding these events.Mean absolute error (MAE) of median RR between the NIV device and the CSM, based on 2326 nights, was 0.78 (SD: 1.96) breaths per minute (brpm). MAE between the IMV device and the CSM was 0.12 brpm (SD: 0.52) for 215 nights. The non-contact device was accepted by the patients and proved to be easy in use. In some of the overall only 13 cases of AECOPD, RR time courses showed variations of increased nocturnal respiratory activity a few days before the occurrence of such events.The present CSM is suitable for valid long-term monitoring of nocturnal RR in patients' home environment and is well accepted by the patients. The exploratory findings related to AECOPD events may serve as a starting point for larger studies aimed at developing robust prediction rules.

Authors

Institutions

Publication Details

Journal
Pneumologie
Published
2025-05-09
DOI
https://doi.org/10.1055/a-2542-5101
Primary Topic
Chronic Obstructive Pulmonary Disease (COPD) Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

At-home validation of a non-contact, radar-based breathing monitor for long-term care of patients with respiratory diseases: A proof-of-concept study

Alina Wildenauer, Christoph Schöbel, Torsten Eggert, Rainer Voisard et al.
1 links
Pneumologie
Chronic Obstructive Pulmonary Disease (COPD) Research
article

At-home validation of a non-contact, radar-based breathing monitor for long-term care of patients with respiratory diseases: A proof-of-concept study

Alina Wildenauer, Christoph Schöbel, Torsten Eggert, Rainer Voisard, Tobit Fischer, Sarah Dietz-Terjung
article en

Abstract

Long-term monitoring of respiratory rate (RR) is an important component in the management of chronic respiratory diseases (CRDs). Specifically, predicting acute exacerbations of chronic obstructive pulmonary disease (AECOPD) is of significant scientific and clinical interest. This study aimed to evaluate the long-term validity of a novel contactless sleep monitor (CSM) in the home environment of CRD patients receiving ventilatory support. Additionally, we assessed patient acceptance, device usability, and RR fluctuations associated with AECOPD to establish a robust foundation for future research.In this prospective proof-of-concept study, nineteen patients requiring non-invasive ventilation (NIV) were provided with the CSM in their home environment for six months and seven patients requiring invasive mechanical ventilation (IMV) for one month. The primary indication for NIV therapy was chronic obstructive pulmonary disease (COPD).The CSM was validated under real-life conditions by comparing its nocturnal RR values with software data from both types of ventilators. Acceptability and usability of the sensor were assessed using a questionnaire. Additionally, COPD exacerbations occurring during the study period were analyzed for potential RR fluctuations preceding these events.Mean absolute error (MAE) of median RR between the NIV device and the CSM, based on 2326 nights, was 0.78 (SD: 1.96) breaths per minute (brpm). MAE between the IMV device and the CSM was 0.12 brpm (SD: 0.52) for 215 nights. The non-contact device was accepted by the patients and proved to be easy in use. In some of the overall only 13 cases of AECOPD, RR time courses showed variations of increased nocturnal respiratory activity a few days before the occurrence of such events.The present CSM is suitable for valid long-term monitoring of nocturnal RR in patients' home environment and is well accepted by the patients. The exploratory findings related to AECOPD events may serve as a starting point for larger studies aimed at developing robust prediction rules.

PneumologieVol. 79(08)
Universität Ulm (DE), Ruhrlandklinik (DE), Bundeswehrkrankenhaus Ulm (DE)
Openalex Percentile: Top 85%
Chronic Obstructive Pulmonary Disease (COPD) Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.