Assessment of blood serum stability with Raman spectroscopy and explanatory AI

This study explores the potential of conventional Raman spectroscopy and commonly used spectral analysis pipelines for rapid and straightforward assessment of degradation in serum samples resulting from storage delays. Serum samples from 18 volunteers were processed within 2 h of extraction, which later on were analyzed via Raman spectroscopy over 4 days, while the corresponding serum vials were kept at room temperature. The resulting spectra were processed, including silicon normalization and a newly proposed outlier detection ensemble method. Next, baseline correction was performed, and spectral unmixing along with Principal Component Analysis (PCA) were applied. Several classification models (KNN, RF, and SVM) were trained and evaluated on three distinct balanced datasets: one including all data, one excluding low signal-to-noise ratio (SNR) data, and one excluding low-SNR data with baseline correction. Feature importance, assessed through random permutations, was used for explainability. Spectral unmixing and PCA indicated limited spectral changes directly attributable to analyte degradation, with inter- and intra-sample variability dominating. Classification results showed that while removing the baseline led to inconclusive results, models trained on datasets retaining the baseline effectively identified non-degraded samples. These findings suggest that while conventional Raman spectroscopy may not be optimally sensitive to subtle analyte variations in serum stored at room temperature, the auto-fluorescence background holds promise as a potential biomarker for monitoring serum storage quality.

Authors

Institutions

Publication Details

Journal
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy
Published
2025-05-09
DOI
https://doi.org/10.1016/j.saa.2025.126297
Citations
4
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
6.54
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Assessment of blood serum stability with Raman spectroscopy and explanatory AI

Olga M. Conde, María Gabriela Fernández-Manteca, Verónica Mieites, Inés Santiuste Torcida et al.
4 citations
Spectrochimica Acta Part A Molecular and Biomolecular Spectroscopy
Spectroscopy Techniques in Biomedical and Chemical Research
6.54
article

Assessment of blood serum stability with Raman spectroscopy and explanatory AI

Olga M. Conde, María Gabriela Fernández-Manteca, Verónica Mieites, Inés Santiuste Torcida, Fidel Madrazo Toca, María José Marín Vidalled
article en
4 citations

Abstract

This study explores the potential of conventional Raman spectroscopy and commonly used spectral analysis pipelines for rapid and straightforward assessment of degradation in serum samples resulting from storage delays. Serum samples from 18 volunteers were processed within 2 h of extraction, which later on were analyzed via Raman spectroscopy over 4 days, while the corresponding serum vials were kept at room temperature. The resulting spectra were processed, including silicon normalization and a newly proposed outlier detection ensemble method. Next, baseline correction was performed, and spectral unmixing along with Principal Component Analysis (PCA) were applied. Several classification models (KNN, RF, and SVM) were trained and evaluated on three distinct balanced datasets: one including all data, one excluding low signal-to-noise ratio (SNR) data, and one excluding low-SNR data with baseline correction. Feature importance, assessed through random permutations, was used for explainability. Spectral unmixing and PCA indicated limited spectral changes directly attributable to analyte degradation, with inter- and intra-sample variability dominating. Classification results showed that while removing the baseline led to inconclusive results, models trained on datasets retaining the baseline effectively identified non-degraded samples. These findings suggest that while conventional Raman spectroscopy may not be optimally sensitive to subtle analyte variations in serum stored at room temperature, the auto-fluorescence background holds promise as a potential biomarker for monitoring serum storage quality.

Spectrochimica Acta Part A Molecular and Biomolecular SpectroscopyVol. 340
Universidad de Cantabria (ES), Instituto de Investigación Marqués de Valdecilla (ES)
Zero hunger
Openalex Percentile: Top 4%
Spectroscopy Techniques in Biomedical and Chemical Research
6.54
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.