Factors affecting vacuum ultraviolet (185 nm) emission intensities in low-pressure mercury lamp photoreactors for photolytic destruction of water contaminants

Direct photolysis by 185 nm vacuum ultraviolet (VUV) photons emitted by low-pressure mercury (LP-Hg) lamps enables destructive treatment of water contaminants that resist degradation by conventional advanced oxidation processes. The treatment challenges associated with poly-/perfluoroalkyl substances, in particular, have renewed interest VUV photolysis, which offers a relatively simple and effective means of PFAS degradation. Since LP-Hg lamps have traditionally been used more widely in ultraviolet-C applications, output data and operational guidelines specific to VUV applications are more difficult to access or measure. Herein, we assessed perfluorobutanoic acid (PFBA) photodegradation efficiency using LP-Hg lamp systems from various manufacturers to gauge the variability in 185 nm output and isolate key design and operational aspects. Results indicated a wide variation in VUV output efficiency, with over a 90 % reduction in electrical energy per order destruction (EE/O) between the least and most effective combinations of lamp, ballast, and quartz sleeves, as a result of their physical design aspects. Furthermore, we found that output efficiency was significantly affected by the steady-state temperature achieved when submerged in the photoreactor, relative to the intended operating temperature of the lamp. Consequently, VUV intensity comparisons performed in an N 2 -purged collimated beam with VUV radiometer were not useful predictors of relative performance when submerged in a photoreactor. The results also suggest that many past laboratory studies of VUV photolytic treatment approaches likely used sub-optimal lamp system configurations, resulting in misleading results with respect to the energy efficiency of VUV treatment. • Low-pressure Hg lamps system configurations have wide variation in 185 nm output. • 254 nm output in low-pressure Hg lamps is not a good indicator of 185 nm output. • N 2 purged collimated beam uncorrelated for low-pressure Hg lamp's intensity in H 2 O • Low-pressure Hg lamps configuration optimization for PFAS photolytic mineralization

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-05-09
DOI
https://doi.org/10.1016/j.jwpe.2025.107909
Citations
1
Primary Topic
Per- and polyfluoroalkyl substances research
Type
article
Field-Weighted Citation Impact
0.86

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Factors affecting vacuum ultraviolet (185 nm) emission intensities in low-pressure mercury lamp photoreactors for photolytic destruction of water contaminants

Ezra L. Cates, D. S. Spicer, Eman Z. Alhamdan
1 citations
Journal of Water Process Engineering
Per- and polyfluoroalkyl substances research
0.86
article

Factors affecting vacuum ultraviolet (185 nm) emission intensities in low-pressure mercury lamp photoreactors for photolytic destruction of water contaminants

Ezra L. Cates, D. S. Spicer, Eman Z. Alhamdan
article en
1 citations

Abstract

Direct photolysis by 185 nm vacuum ultraviolet (VUV) photons emitted by low-pressure mercury (LP-Hg) lamps enables destructive treatment of water contaminants that resist degradation by conventional advanced oxidation processes. The treatment challenges associated with poly-/perfluoroalkyl substances, in particular, have renewed interest VUV photolysis, which offers a relatively simple and effective means of PFAS degradation. Since LP-Hg lamps have traditionally been used more widely in ultraviolet-C applications, output data and operational guidelines specific to VUV applications are more difficult to access or measure. Herein, we assessed perfluorobutanoic acid (PFBA) photodegradation efficiency using LP-Hg lamp systems from various manufacturers to gauge the variability in 185 nm output and isolate key design and operational aspects. Results indicated a wide variation in VUV output efficiency, with over a 90 % reduction in electrical energy per order destruction (EE/O) between the least and most effective combinations of lamp, ballast, and quartz sleeves, as a result of their physical design aspects. Furthermore, we found that output efficiency was significantly affected by the steady-state temperature achieved when submerged in the photoreactor, relative to the intended operating temperature of the lamp. Consequently, VUV intensity comparisons performed in an N 2 -purged collimated beam with VUV radiometer were not useful predictors of relative performance when submerged in a photoreactor. The results also suggest that many past laboratory studies of VUV photolytic treatment approaches likely used sub-optimal lamp system configurations, resulting in misleading results with respect to the energy efficiency of VUV treatment. • Low-pressure Hg lamps system configurations have wide variation in 185 nm output. • 254 nm output in low-pressure Hg lamps is not a good indicator of 185 nm output. • N 2 purged collimated beam uncorrelated for low-pressure Hg lamp's intensity in H 2 O • Low-pressure Hg lamps configuration optimization for PFAS photolytic mineralization

Journal of Water Process EngineeringVol. 75
Primary Source (US), Clemson University (US)
Strategic Environmental Research and Development Program
Clean water and sanitation
Openalex Percentile: Top 28%
Per- and polyfluoroalkyl substances research
0.86
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.