Analysis and Implications of Compliance on Joint Biomechanics Measurements in Superposition Testing

To quantify the contributions of specific ligaments to overall joint movement, the principle of superposition has been used for nearly 30 years. This principle relies on using a robotic test system to move a biological joint to the same position before and after transecting a specific ligament. The resulting difference in joint forces is assumed to be the transected ligament's tension. However, the robotic test system's ability to accurately return the joint to the commanded pose is dependent on the compliance of the system's various components, which is often neglected. Accordingly, there were three objectives in this paper: (1) Explain the influence of system compliance on positioning error in superposition testing with a mathematical model, (2) Quantify the compliance of components within the robotic test system, and (3) Provide a framework to evaluate uncertainty in published superposition based in situ force measurements and demonstrate their implications on published anterior cruciate ligament (ACL) forces. A system stiffness model (SSM) was derived to explain that compliance of test system components will cause the superposition method to underestimate ligament tension and stiffness. Based on typical test system component and joint stiffness ranges measured in this study, it was determined that with decreasing robot and/or bone stiffness, or increasing joint stiffness values, ligament load error could increase to values greater than 50%. Results indicate that experimentalists should (1) maximize test system component stiffness relative to joint stiffness and/or (2) compensate for compliance induced deflection of the test system components.

Authors

Institutions

Publication Details

Journal
Journal of Biomechanical Engineering
Published
2025-05-09
DOI
https://doi.org/10.1115/1.4068634
Citations
1
Primary Topic
Knee injuries and reconstruction techniques
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis and Implications of Compliance on Joint Biomechanics Measurements in Superposition Testing

Callan M. Gillespie, Naomi B. Haas, Robb Colbrunn, Tara F. Nagle
1 citations
Journal of Biomechanical Engineering
Knee injuries and reconstruction techniques
2.01
article

Analysis and Implications of Compliance on Joint Biomechanics Measurements in Superposition Testing

Callan M. Gillespie, Naomi B. Haas, Robb Colbrunn, Tara F. Nagle
article en
1 citations

Abstract

To quantify the contributions of specific ligaments to overall joint movement, the principle of superposition has been used for nearly 30 years. This principle relies on using a robotic test system to move a biological joint to the same position before and after transecting a specific ligament. The resulting difference in joint forces is assumed to be the transected ligament's tension. However, the robotic test system's ability to accurately return the joint to the commanded pose is dependent on the compliance of the system's various components, which is often neglected. Accordingly, there were three objectives in this paper: (1) Explain the influence of system compliance on positioning error in superposition testing with a mathematical model, (2) Quantify the compliance of components within the robotic test system, and (3) Provide a framework to evaluate uncertainty in published superposition based in situ force measurements and demonstrate their implications on published anterior cruciate ligament (ACL) forces. A system stiffness model (SSM) was derived to explain that compliance of test system components will cause the superposition method to underestimate ligament tension and stiffness. Based on typical test system component and joint stiffness ranges measured in this study, it was determined that with decreasing robot and/or bone stiffness, or increasing joint stiffness values, ligament load error could increase to values greater than 50%. Results indicate that experimentalists should (1) maximize test system component stiffness relative to joint stiffness and/or (2) compensate for compliance induced deflection of the test system components.

Journal of Biomechanical EngineeringVol. 147(8)
Cleveland State University (US), Cleveland Clinic (US), Cleveland Foundation (US), Cleveland Clinic Lerner College of Medicine (US)
Openalex Percentile: Top 16%
Knee injuries and reconstruction techniques
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.