Novel Focused Ion Beam Techniques for Enhanced Sample Preparation for <i>In Situ</i> Transmission Electron Microscopy Heating and Irradiation Experiments

Focused ion beam (FIB) systems have revolutionized sample preparation for transmission electron microscopy (TEM), enabling precise and site-specific material analysis. However, the conventional ion beam-induced deposition (IBID) approach to preparing FIB samples can lead to contamination effects that can compromise the quality of TEM data acquisition. This study introduces an innovative FIB method for connecting TEM lamellae to support grids via redeposition, avoiding the contamination issue. We demonstrate the effectiveness of this technique through observations of a SiC phase within tristructural-isotropic particles during in situ high-temperature and irradiation TEM experiments, establishing an improved process for characterizing material behaviors during exposure to their industrially relevant environmental conditions.

Authors

Institutions

Publication Details

Journal
Microscopy and Microanalysis
Published
2025-05-09
DOI
https://doi.org/10.1093/mam/ozaf029
Citations
2
Primary Topic
Advanced Electron Microscopy Techniques and Applications
Type
article
Field-Weighted Citation Impact
5.10
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Focused Ion Beam Techniques for Enhanced Sample Preparation for In Situ Transmission Electron Microscopy Heating and Irradiation Experiments

Kerui Wei, Graeme Greaves, Anamul H. Mir, M. W. Lindley et al.
2 citations
Microscopy and Microanalysis
Advanced Electron Microscopy Techniques and Applications
5.10
article

Novel Focused Ion Beam Techniques for Enhanced Sample Preparation for In Situ Transmission Electron Microscopy Heating and Irradiation Experiments

Kerui Wei, Graeme Greaves, Anamul H. Mir, M. W. Lindley, Xuzhao Liu, Ping Xiao, Philip J. Withers, Sarah J. Haigh, Xiangli Zhong, João Paulo Martins, Junquan Lao
article en
2 citations

Abstract

Focused ion beam (FIB) systems have revolutionized sample preparation for transmission electron microscopy (TEM), enabling precise and site-specific material analysis. However, the conventional ion beam-induced deposition (IBID) approach to preparing FIB samples can lead to contamination effects that can compromise the quality of TEM data acquisition. This study introduces an innovative FIB method for connecting TEM lamellae to support grids via redeposition, avoiding the contamination issue. We demonstrate the effectiveness of this technique through observations of a SiC phase within tristructural-isotropic particles during in situ high-temperature and irradiation TEM experiments, establishing an improved process for characterizing material behaviors during exposure to their industrially relevant environmental conditions.

Microscopy and MicroanalysisVol. 31(3)
University of Huddersfield (GB), University of Manchester (GB), Henry Royce Institute (GB)
Life in Land
Openalex Percentile: Top 6%
Advanced Electron Microscopy Techniques and Applications
5.10
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.