Research on Accurate Fault Location of Multi-Terminal DC Distribution Network

The rise of direct current (DC) distribution networks, driven by distributed energy storage and large-scale photovoltaic integration, has significantly altered distribution network configurations. In DC networks, short-circuit faults cause a sharp drop in voltage and a rapid increase in current, negatively impacting system stability. To solve this problem, we used an improved red fox optimization (IRFO) algorithm to calculate the distance to failure of the protection device. The algorithm shows higher convergence and accuracy compared to conventional methods. The isolated forest algorithm rejects anomalous data, while an adjustable feedback factor and genetic crossover operator further improve performance. Adaptive interpolation is employed to address low sampling frequency issues, enhancing fault localization precision. Simulations performed in Simulink show that the method is highly resistant to interference with minimal localization error. It is also resistant to changes in system parameters, highlighting its robustness and usefulness in fault localization.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-05-08
DOI
https://doi.org/10.3390/electronics14101910
Primary Topic
HVDC Systems and Fault Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on Accurate Fault Location of Multi-Terminal DC Distribution Network

Zhuolin Chen, Qing Liu
Electronics
HVDC Systems and Fault Protection
article

Research on Accurate Fault Location of Multi-Terminal DC Distribution Network

Zhuolin Chen, Qing Liu
article en

Abstract

The rise of direct current (DC) distribution networks, driven by distributed energy storage and large-scale photovoltaic integration, has significantly altered distribution network configurations. In DC networks, short-circuit faults cause a sharp drop in voltage and a rapid increase in current, negatively impacting system stability. To solve this problem, we used an improved red fox optimization (IRFO) algorithm to calculate the distance to failure of the protection device. The algorithm shows higher convergence and accuracy compared to conventional methods. The isolated forest algorithm rejects anomalous data, while an adjustable feedback factor and genetic crossover operator further improve performance. Adaptive interpolation is employed to address low sampling frequency issues, enhancing fault localization precision. Simulations performed in Simulink show that the method is highly resistant to interference with minimal localization error. It is also resistant to changes in system parameters, highlighting its robustness and usefulness in fault localization.

ElectronicsVol. 14(10)
North China Electric Power University (CN)
State Grid Corporation of China
Openalex Percentile: Top 92%
HVDC Systems and Fault Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.