Case Report Endovascular single-chamber pacemaker implantation using active fixation in a 8 years old Dogue de Bordeaux with presumed Persistent Atrial Standstill: the first case documented in Romania

Background: Symptomatic bradyarrhythmias in dogs can lead to sever hemodynamical compromise due to impaired oxygen and nutrients delivery and even sudden cardiac death. In cases refractory to medical therapy the heart rate and therefore the cardiac output are maintained in physiological ranges using artificial external, internal and temporary (emergency situations) or internal and permanent cardiac pacing. Methods: This case report documents the implantation of a permanent transvenous Pacemaker using active fixation, for the first time in Romania in a 8 years old canine Dogue de Bordeaux with a suspicion (on surface electrocardiography) of Persistent Atrial Standstill. The diagnostic in this atrial muscular dystrophy requires differentiation from Atrial Fibrillation with Third Degree Atrioventricular Block using Cardiac Mapping, but in emergency situations or progressive Congestive Heart Failure the decision to implant the pacemaker should be based on the hemodynamical effects of the dysrhythmia and the definitive diagnostic should be made during the implantation of the device. Results: We succesfully implanted in this case a transvenous ventricular Solia S60 lead at the level of the 1/2 distance between the mid-septal and right ventricular apex that was connected to the subcutaneousely placed Pulse Generator (Enitra 6 SR). The survival after the procedure was 202 days (6 months and 18 days) and the patient's death was not related to a cardiac cause. The necropsy showed that the active fixation in this case was preserved and there were not identified any local rejections of the lead or at the site of the pulse generator. Conclusions: The outcome of the patient was positive regarding the described cardiac function in this case and the clinical signs went into remission shortly after the pacing.

Authors

Institutions

Publication Details

Journal
Cluj Veterinary Journal
Published
2024-12-30
DOI
https://doi.org/10.52331/v29i4x55
Primary Topic
Cardiovascular Syncope and Autonomic Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Case Report Endovascular single-chamber pacemaker implantation using active fixation in a 8 years old Dogue de Bordeaux with presumed Persistent Atrial Standstill: the first case documented in Romania

Alexandru Nechifor, F Leca, Florica Bărbuceanu, Ștefan Adrian Geantă et al.
Cluj Veterinary Journal
Cardiovascular Syncope and Autonomic Disorders
article

Case Report Endovascular single-chamber pacemaker implantation using active fixation in a 8 years old Dogue de Bordeaux with presumed Persistent Atrial Standstill: the first case documented in Romania

Alexandru Nechifor, F Leca, Florica Bărbuceanu, Ștefan Adrian Geantă, Mihaela Claudia Bolintineanu, Eusebiu Ionut Condurachi, Daniel Barsan, Nicu Caplea, Diana Caraza
article en

Abstract

Background: Symptomatic bradyarrhythmias in dogs can lead to sever hemodynamical compromise due to impaired oxygen and nutrients delivery and even sudden cardiac death. In cases refractory to medical therapy the heart rate and therefore the cardiac output are maintained in physiological ranges using artificial external, internal and temporary (emergency situations) or internal and permanent cardiac pacing. Methods: This case report documents the implantation of a permanent transvenous Pacemaker using active fixation, for the first time in Romania in a 8 years old canine Dogue de Bordeaux with a suspicion (on surface electrocardiography) of Persistent Atrial Standstill. The diagnostic in this atrial muscular dystrophy requires differentiation from Atrial Fibrillation with Third Degree Atrioventricular Block using Cardiac Mapping, but in emergency situations or progressive Congestive Heart Failure the decision to implant the pacemaker should be based on the hemodynamical effects of the dysrhythmia and the definitive diagnostic should be made during the implantation of the device. Results: We succesfully implanted in this case a transvenous ventricular Solia S60 lead at the level of the 1/2 distance between the mid-septal and right ventricular apex that was connected to the subcutaneousely placed Pulse Generator (Enitra 6 SR). The survival after the procedure was 202 days (6 months and 18 days) and the patient's death was not related to a cardiac cause. The necropsy showed that the active fixation in this case was preserved and there were not identified any local rejections of the lead or at the site of the pulse generator. Conclusions: The outcome of the patient was positive regarding the described cardiac function in this case and the clinical signs went into remission shortly after the pacing.

Cluj Veterinary JournalVol. 29(4)
Institutul National de Sanatate Publica (RO), Society of Interventional Radiology (US), OMV Petrom (Romania) (RO), Institute for Diagnosis and Animal Health (RO), University of Veterinary Medicine (HU), Biotronik (Germany) (DE), Biotronik (Switzerland) (CH)
Openalex Percentile: Top 52%
Cardiovascular Syncope and Autonomic Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.