A Simple Thermoelectrical Surface Approach for Numerically Studying Dry Band Formation on Polluted Insulators

This paper presents a simple thermoelectrical temporal surface method for numerically studying the appearance of a dry band on a polluted insulator. The proposed method combines an empirical expression of the pollution layer surface conductivity, expressed as a function of the temperature and equivalent salt deposit density (ESDD), and a surface approach for modeling the pollution layer, using thermoelectrical temporal simulations based on the finite element method (FEM). Using different material substrates, pollution layer thicknesses, and ESDD levels, the reliability and limitations of the simple thermoelectrical numerical model have been studied. The numerical results obtained demonstrated that the proposed thermoelectrical model can dynamically simulate the dry band appearance in accordance with the experimental results in terms of the temporal evolution of the temperature and the pollution layer resistance, as well as the evolution of the voltage drop and E-field along the dry band formation zone. The results also demonstrate the influence of the material substrate and the pollution layer thickness, which directly influence the thermal aspect of the dry band formation. The simple thermoelectrical numerical surface model was used to study the dry band appearance on a uniformly polluted 69 kV insulator. The results obtained enabled a dynamic simulation of the appearance of the first dry band, which appeared in the middle of the insulator, and to deeply investigate the evolution of the surface temperature, electric potential, and E-field distributions along the insulator. The proposed simple thermoelectrical model combined with the empirical model is able to simulate the influence of a non-uniform pollution layer. Hence, the proposed model provides a simple numerical tool for studying the evolution of the potential and E-field distributions along uniformly and non-uniformly polluted insulation equipment to identify the probability of a region of high dry band appearance relative to the insulator material and geometry. This can aid in the development of new types of mitigation methods to improve the performance of all types of insulators under polluted conditions.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-05-08
DOI
https://doi.org/10.3390/en18102412
Primary Topic
Acoustic Wave Phenomena Research
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Simple Thermoelectrical Surface Approach for Numerically Studying Dry Band Formation on Polluted Insulators

C. Volat, G. Kone, Marc‐Alain Andoh
4 links
Energies
Acoustic Wave Phenomena Research
article

A Simple Thermoelectrical Surface Approach for Numerically Studying Dry Band Formation on Polluted Insulators

C. Volat, G. Kone, Marc‐Alain Andoh
article en

Abstract

This paper presents a simple thermoelectrical temporal surface method for numerically studying the appearance of a dry band on a polluted insulator. The proposed method combines an empirical expression of the pollution layer surface conductivity, expressed as a function of the temperature and equivalent salt deposit density (ESDD), and a surface approach for modeling the pollution layer, using thermoelectrical temporal simulations based on the finite element method (FEM). Using different material substrates, pollution layer thicknesses, and ESDD levels, the reliability and limitations of the simple thermoelectrical numerical model have been studied. The numerical results obtained demonstrated that the proposed thermoelectrical model can dynamically simulate the dry band appearance in accordance with the experimental results in terms of the temporal evolution of the temperature and the pollution layer resistance, as well as the evolution of the voltage drop and E-field along the dry band formation zone. The results also demonstrate the influence of the material substrate and the pollution layer thickness, which directly influence the thermal aspect of the dry band formation. The simple thermoelectrical numerical surface model was used to study the dry band appearance on a uniformly polluted 69 kV insulator. The results obtained enabled a dynamic simulation of the appearance of the first dry band, which appeared in the middle of the insulator, and to deeply investigate the evolution of the surface temperature, electric potential, and E-field distributions along the insulator. The proposed simple thermoelectrical model combined with the empirical model is able to simulate the influence of a non-uniform pollution layer. Hence, the proposed model provides a simple numerical tool for studying the evolution of the potential and E-field distributions along uniformly and non-uniformly polluted insulation equipment to identify the probability of a region of high dry band appearance relative to the insulator material and geometry. This can aid in the development of new types of mitigation methods to improve the performance of all types of insulators under polluted conditions.

EnergiesVol. 18(10)
Université du Québec à Chicoutimi (CA)
Natural Sciences and Engineering Research Council of Canada
Openalex Percentile: Top 91%
Acoustic Wave Phenomena Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.